Kübler CODIX 533 Mode D'emploi page 22

Générateur de consigne
Masquer les pouces Voir aussi pour CODIX 533:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

1 sec
2. The function
page 9
SiGnal allows selecting
the setpoint output in volts or mA.
time allows selecting
the time in seconds or minutes.
Number of PEriods
allows defining the number of refer-
ence points.
output 1 allows select-
ing the value of the current or volt-
age for the first reference point.
PEriod. 1 allows defin-
ing the first period.
(A maximum of 20 periods may be
programmed) The maximum set-
points ou. X and the times PE. X
result from the setting of PEr.
The function cYcle
allows defining the number of cycles
to be carried out.
Selecting noCYcle will
start an endless loop.
8
to
to
to
see
Press both keys simultaneously to
switch over to the following parameter.
Within a parameter, select the decade
with the left key and select a value
from 0 ... 9 with the right key.
3. After setting the value of cYcl,
press both keys simultaneously;
the following message is displayed:
4. Use the right key to select YES or
no
5. If YES is selected, press both
keys simultaneously to end the
programming
6. The device is now ready for
operation. Press the right key to
start it and the left key to stop it.
www.kuebler.com

Publicité

Table des Matières
loading