9.

Maintenance

Before carrying out any work, disconnect the pump from the electrical system and secure it from
being accidentally switched on again. Check the discharge pipe line for damage. To ensure that the
pump operates smoothly, we recommend regular cleaning of the inlet strainer to remove fibres and
other clinging material.
The level control function will fail to operate properly if surface dirt is allowed to accumulate on the
sensors. Regular cleaning of the sensors is recommended for optimum performance.
The vent nozzle must be checked for alignment and passage, and if necessary, realigned and cleaned.
If there are problems, please contact your GC partner.
To avoid danger if the power cable is damaged, it must be replaced by the manufacturer or its
service agent or a similarly qualified person.
a
b
Adjust the cap of the air vent nozzle (a)
so that the 1 mm opening (b) is aligned
to the left.
Figure 2
27