6.

Transport

Carry the pump by the carrying handle only, not by the electrical connecting cable or sensor cover. Do
not bump or drop it. When lowering the pump into deep sumps or pits, use a rope or chain.
7.

Electrical connection

/
Observe the correct operating voltage (see "Technical Data").
/
Never place the power plug in the water.
/
Connect the pump to a properly installed electrical socket (in compliance with the power supp-
ly company regulations) protected by at least a 10 A (slow-blowing) fuse.
/
For submersible pumps of protection classification I, all exposed conductive parts are con-
nected with a protective earth conductor. Before the pump is put into operation, an electrically
skilled person must check that the protective earth cable is properly connected.
/
When operating pumps of protection class I, the following applies according to IEC 335-2-
41:1984, Amendment 1:1990: Pumps of protection class I intended for use in swimming pools
or garden ponds must be equipped with a residual-current device (max. 30 mA) in the supply
line. The pump may not be operated if any persons are in the pool.
/
Temperatures higher than those permitted cause the pump to be shut off by the temperature
limiter. After the temperature limiter is triggered, disconnect the pump from the electric system
before correcting the cause of the fault, otherwise it will switch on automatically once cooled
down.