ANTENNA 433MHz
For control panels working at 433,92 MHz, the antenna is also in this case
already connected (wire billet in the RIB control panel), however, if it is
necessary to install the antenna to attain greater range, connect it to terminals
1-2 if MASTER Wi-Fi WITH TERMINAL BOARD, or to the terminals dedicated to
antenna connection on RIB control panels.
NOVA Wi-Fi AND VERTIGO Wi-Fi PHOTOCELL ALARM SIGNAL CHECK
Check that by taking the battery out of the photocell receiver with micro-switch, for example
3 in the ON on position, and commanding the door to open, the dual-color LED3 on the
MASTER Wi-Fi alternates green and red , while LEDs DL2 and DL3 turn off, and that the
buzzer emits an alternating sound for 1 minute.
Repeat the check for any other photocell receivers installed.
Note: if when removing the battery and commanding the door to open the buzzer on the
MASTER Wi-Fi does not sound, micro-switch 3 on the MASTER Wi-Fi is in the OFF position
(go-ahead not enabled). Turn it to ON.
TOUCH Wi-Fi STRIP ALARM SIGNAL CHECK
Check that by taking the battery out of the transmitter with micro-switch, for example DIP3
in the ON position, the dual-color LED EDGE PHOT 3 on the MASTER Wi-Fi lights flashing
red while LED DL2 turns off, and that the buzzer emits every 3 seconds sound for 1 minute.
Repeat the check for any other strips installed.
Note: if the battery is removed and the buzzer on the MASTER Wi-Fi does not sound, micro-
switch 3 on the MASTER Wi-Fi is in the OFF position (go-ahead not enabled). Turn it to ON.
WARNING (replace the batteries)
The WARNING tells the user of the immediate need to replace the batteries.
When battery power reaches 2,3V for NOVA Wi-Fi and 3V for TOUCH Wi-Fi, the NOVA Wi-Fi
photocell receiver or the strip signal the MASTER Wi-Fi via radio of the low battery status
and activate the BUZZER of the MASTER Wi-Fi with a sound every 3 seconds for 1 minute.
The warning is renewed for 1 minute if a command is given to the door.
The dual-color LED on the MASTER Wi-Fi corresponding to the photocell or the strip with the
low batteries emits a constant red light.
The SPARK Wi-Fi blinker (if available) indicates the warning by emitting 2
consecutive flashes followed by a pause for 3 seconds for the duration of the
opening or closing of the door.
The system is still operational during these signals, but it is advantageous to replace the
batteries as soon as possible in order to avoid a full stop of the door operation which
happens when the batteries reach 2,0 V for NOVA Wi-Fi and 2,7 V for TOUCH Wi-Fi.
ALARM (batteries completely exhausted or not working)
The alarm activates when the batteries are completely exhausted (2V for NOVA Wi-Fi and
2,7V for TOUCH Wi-Fi) or when they stop working.
On MASTER Wi-Fi the LEDs DL2 and DL3 turn off MASTER Wi-Fi blocks the automation.
On MASTER Wi-Fi the dual-color LED corresponding to the photocell or the strip with the
low or non-functioning batteries flashes red. The BUZZER emits a sound every 3 seconds
for 1 minute, while the SPARK Wi-Fi blinker (if available) signals the alarm status
by emitting emitting 2 consecutive flashes followed by a pause for 3 seconds,
notifying the user that the batteries must be replaced or repaired.
The alarm is renewed for 1 minute if a command is given to the door.
REPLACING THE BATTERIES
The lifespan of the 1.5 V AA batteries used in the safety devices is about 3 years.
In case it is required to replace the batteries, it will not be necessary to re-program the
photocells, nor any other RIB Wi-Fi accesories.
- Identify the safety device with the exhausted batteries by checking the diagnostic of the
LED EDGE PHOT on the MASTER Wi-Fi.
- Using the number on the side of the dual-color LED EDGE PHOT which is flashing red or
that emits a constant red light identify the number of the safety device with the exhausted
batteries.
- Find the NOVA Wi-Fi or TOUCH Wi-Fi device with the adhesive strip bearing the
identification number corresponding to the number of the dual-color LED which is in alarm
status on the MASTER Wi-Fi.
- Replace the batteries, checking that the polarity is correct.
- Push button PROG TX on the NOVA Wi-Fi or TOUCH Wi-Fi to restart the MASTER Wi-Fi.
- The buzzer on the strip of the MASTER Wi-Fi will turn off and the LEDs DL2- DL3 (if in
alarm status) will come on. The dual-color LED corresponding to the safety device with the
replaced batteries will turn off.
The automation is now ready for safe operation.
ATTENTION: Please remember that batteries must be disposed of properly according to
current standards. In case of disposal of the safety devices please remember to remove the
AA batteries and dispose of them properly
TOTAL REMOVAL PROCEDURE FOR MEMORIZED SAFETY DEVICES
To perform a total removal of the safety devices (NOVA Wi-Fi and TOUCH Wi-Fi)
recorded in the MASTER Wi-Fi memory just push and hold the button PROG. RX for 10
seconds. After 10 seconds all of the dual-color LEDs (from EDGE PHOT 1 to EDGE PHOT 6)
will flash alternately 6 times, indicating successful removal.
Afterwards the dual-color LED EDGE PHOT and LEDs DL2 and DL3 will turn off.
ATTENTION: WITH LED DL2 AND DL3 OFF AUTOMATION DOES NOT WORK.
REMOVAL PROCEDURE FOR A SINGLE SAFETY DEVICE (PHOTOCELL OR STRIP)
In order to remove a single memorized safety device on the MASTER Wi-Fi, use
the following procedure:
- Push the button PROG. RX one or more times to select the dual-color LED EDGE PHOT
which begins flashing green, corresponding to the safety device to be eliminated.
- After selecting the safety device, push and hold the button PROG. RX for 10 seconds.
- After 10 seconds the dual-color LED EDGE PHOT flashes alternately red and green 6 times,
indicating successful removal.
ATTENTION: Place the micro-switch corresponding to the eliminated safety device in
the OFF position, then scan the dual-color LED pushing the button PROG. RX 6 times.
IMPORTANT: Remove the batteries from the eliminated safety device.
H -
PROGRAMMING THE SPARK Wi-Fi BLINKER
- Push and hold the button PROG. RX on the MASTER Wi-Fi for at least 3 seconds.
- After releasing the button PROG. RX the dual-color LED DL7 will begin flashing red for
10 seconds.
- Push the button S4 PROG. TX on the SPARK Wi-Fi blinker to send a radio signal to the
MASTER Wi-Fi.
- Successful memorization is indicated by a sound from the buzzer and the red dual-color
LED DL7 on the MASTER Wi-Fi turning green, while the red LED DL7 on the SPARK Wi-Fi
card flashes 3 times.
- Allow 10 seconds to pass to conclude programming, or push button PROG. RX on the
MASTER Wi-Fi for a moment.
- Replace the casing.
- Mount the diffuser and attach it with the screws provided.
More than one blinker can be memorized by the MASTER Wi-Fi.
Each SPARK Wi-Fi blinker receives during the memorization one single identic code from the
MASTER Wi-Fi to which it is paired up.
When the MASTER Wi-Fi is activated by a command, all SPARK Wi-Fi blinkers memorized in
it will start blinking simoultanesly.
P
ROGRAMMING REMOTE CONTROLS FOR TOTAL OPENING (maximum of
100 codes)
Using the following procedure it is possible for MASTER Wi-Fi to memorize the following
remote controls:
SUN 2CH 433 MHz
SUN 4CH 433 MHz
SUN CLONE 2CH 433 MHz
SUN CLONE 4CH 433 MHz
BLOCK Wi-Fi KEY SELECTOR 433 MHz
At MASTER Wi-Fi start-up the yellow LED DL6 will turn on. At the same time the buzzer will
emit a sound indicating proper power status.
a - If the MASTER Wi-Fi memory is empty (default) the dual-color LED DL7 flashes
alternately red and green.
b - If codes are already present in the memory, the dual-color LED DL7 remains off (perform
a total removal - see paragraph TOTAL CODE REMOVAL PROCEDURE).
In addition to the codes, MASTER Wi-Fi also learns the channels that are desired
for use. Be careful to remember the buttons pushed on the remote controls during
the code memorization procedure as they will be those used thereafter for the
total opening.
If no code is sent, after 10 seconds the red dual-color LED DL7 on the MASTER Wi-Fi turns
off indicating the end of the programming procedure.
- Push and hold the button PROG RX for at least 3 seconds. After release the dual-color LED
DL7 on the MASTER Wi-Fi flashes red for 10 seconds.