Ribind MASTER Wi-Fi Mode D'emploi page 21

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

D
- CONNECTING THE MASTER Wi-Fi CARD
ATTENTION: The use of the product inside of metal containers can cause a system-malfunction. It is therefore recommended in these cases to add the aerial code
ACG5451 to apply to the metal casing for a perfect reception/transmission of the signals.
ATTENTION: ACTIVATE ON CONTROL PANELS THE PRE-FLASHING FUNCTION (IF AVAILABLE).
It is strongly advisable to avoid using an automatic closing time delay, not longer than 1 minute.
Verify the presence of protection fuse in series on secondary of the control panel. In case it is not available, please connect a T 200 mA delayed fuse in series on the MASTER
power supply.
- Turn off power to the automation control panel.
NOTE: The opening of the gate occurs 2 seconds after receiving a radio or push button command. That is done to allow the MASTER Wi-Fi card to verify the presence and correct functioning
of the memorized safety devices.
PED
green wire
COM
gray wire
EDGE
yellow wire
PHOT.N.C.
black wire
CONTROL BUTTON
white wire
A/D+ TEST
brown wire
10 9
The Wi-Fi system is operating normally if he handles
all the radio controls (through its 433 MHz radio
module) and the wired controls (through its white
wire).
In case of using radio receivers and wired controls
(and therefore external to the Wi-Fi system), for a
correct functioning of the system, these commands
must be connected through the white wire of the
MASTER Wi-Fi.
!
* OBLIGATORY connection for panels with a 120/230V ac blinker output
** OBLIGATORY connection for panels with a 12/24V ac/dc blinker output.
ATTENTION: CHECK POLARITY
The connection is compulsory also in those cases where the blinker is not
installed in the system.
ATTENTION: Always connect the control panel blinker output to the MASTER
Wi-Fi card with one of the dedicated terminals, depending on whether the
blinker is 230V or connected to the wires of the J2 connector for 12/24V. If the
connection is not made the door will not work and the buzzer emits 4 sounds
indicating that the connection is missing.
PEDESTRIAN CONTROL (gray wire COM, green wire PED) dedicated to pedestrian
radio-control.
EDGE INPUT (gray wire COM, yellow wire EDGE) dedicated to the strip safety device.
Attention: any wire jumper present on the SAFETY STRIP terminals of control panels must
be removed.
PHOTOCELL INPUT (gray wire COM, black wire PHOT) dedicated to
the photocell safety devices.
Attention: any wire jumper present on the COM-PHOT terminals of RIB control panels
must be removed.
6 5
2 1
+ -
6 5 4 3 2 1
+ -
CONTROL BUTTON (gray wire COM, white wire N.O. BUTTON)
Disconnect every wired command from the control panel and connect it to this white wire
of MASTER Wi-Fi.
CONNECTION OF THE AUTO TEST INPUT (brown wire A/D+ TEST) for compliance
with standard EN13849-2:2008
- If the panel used is equipped with auto test place jumper JP1 as indicated in
the "SELF-TEST-ENABLED RIB ELECTRONIC BOARD CHART" or by the control panel
power supply used (see relative instructions).
- Connect the auto test output of the control panel to the A/D+ TEST terminal of the MASTER
Wi-Fi card in order to be able to control the system at the end of every complete automated
opening.
- Closing will only occur when the MASTER Wi-Fi card has passed the
control test.
- If the MASTER Wi-Fi card control test fails, the control panel will block the
automation, the dual-color LED on the MASTER Wi-Fi card indicates a safety outage,
alternately flashing red and green.
The buzzer emits an alternating sound for 1 minute to signal the problem.
The alarm status of the buzzer comes on again for 1 minute when a control is given.
If the panel is not equipped with an auto test, the control test is ignored.
21
21
*
120/230V ac
!
+
**
-
12/24V ac/dc
12/24V ac/dc
1
central antenna 433 MHz
2
ground-plane antenna 433 MHz
3
negative power feed 12/24V ac/dc
4
positive power feed 12/24V ac/dc
5-6 connects at the total open/close input command
in the control panel
G
B

Publicité

Table des Matières
loading

Produits Connexes pour Ribind MASTER Wi-Fi

Ce manuel est également adapté pour:

Ep10706772Ep2345019Master wi-fi fr

Table des Matières