Your room heater comes packed in a single carton. Before installation, check the rating plate to verify that the Model
Number is correct and that the room heater is equipped for the type gas you intend to use.
TYPE
Closed Front
Height
Width
Depth
Input (BTU / HR)
Gas Inlet / Outlet Size
Vent Size
Center of Vent Floor
Approximate Shipping Weight
Optional Blower Model
THIS IS A GAS-FIRED, GRAVITY VENTED ROOM HEATER THAT WILL OPERATE SAFELY AND PROVIDE AN EFFICIENT
SOURCE OF HEAT WHEN INSTALLED, OPERATED AND MAINTAINED AS RECOMMENDED IN THESE INSTALLATION
AND OPERATING INSTRUCTIONS. READ THESE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING, SERVICING,
OR USING THIS APPLIANCE. IF YOU DO NOT UNDERSTAND ANY PART OF THESE INSTRUCTIONS, CONSULT
LOCAL AUTHORITIES, OTHER QUALIFIED INSTALLERS, SERVICE TECHNICIAN, THE GAS SUPPLIER, OR THE
MANUFACTURER.
This heater must be connected to a properly installed and maintained venting system. This heater is equipped with a manual
reset vent safety shut-off device. Pilot burner outage will occur if the heater is not connected to a vent system. Pilot burner outage
may occur due to restriction or blockage in the vent or if connected to a masonry chimney having an area greater than the vent
size shown above. This appliance should be vented through a properly sized listed type B vent that has been constructed in
accordance with the National Building Code. If a horizontal section of vent is used, it must slope upwards a minimum of ¼ inch
per foot of length.
This heater must not be connected to a vent system being used for wood or coal burning appliances. The use of more than one
appliance per vent system will most likely cause the vent safety shut-off device to shut off the heater due to the cooling of vent
temperatures through the draft diverter of the second appliance. In some situations, the vent safety shut-off may shut down the
heater if a large, unlined, masonry chimney is used. Due to low vent temperatures associated with more efficient heaters it may
take too long to get the vent action going in a chimney before the shut-off device will shut down the heater. If this is the case, we
recommend lining the chimney with the proper size type B vent pipe or type B chimney liner.
WARNING: Do NOT bypass the vent safety shutoff switch. To do so could expose
the consumer to property damage, personal injury or possible death.
The switch, when activated, will extinguish the burner flame. If the homeowner experiences this problem, the vent system must
be checked and corrected.
ROOM HEATER SPECIFICATIONS
CONTROL
GAS
Thermostat Bulb
Natural

INTRODUCTION

VENTING

VC201C
20"
24"
15-1/4"
20,000
1/2 x 3/8"
3"
16-1/2"
59 lbs
N / A
Page 3

MODEL NUMBERS

VC351C
VC501C
26"
30"
15-1/4"
19-1/4"
35,000
50,000
1/2 x 3/8"
1/2 x 3/8"
4"
21-1/2"
21-1/2"
85 lbs
102 lbs
CHB-3
26"
30"
4"
CHB-3
1017755-B