3

Configuration

Caution
The node contains electrostatically sensitive compo-
nents. The node will be damaged if you touch the con-
tact surfaces of the plug connectors or if you do not
observe the regulations for handling electrostatically
sensitive components.
Proceed as follows when configuring:
1. Switch off the power supply.
2. Open the switch cover.
3. Use the rotary/DIL switches to set the following
(see section 4):
– the field bus address
– the diagnostic message active/inactive.
4. Screw the switch cover tight again.
5. If the CP system is the first or last field bus slave, the
terminating resistor in the Festo Sub-D plug must be
activated.
Warning
S Check the measures required for putting your system
into a safe status in the event of an EMERGENCY
STOP.
Further information can be found in manual
P.BE-CP-FB13-E-.. .