Daikin DZ17VSA Instructions D'installation page 43

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

c
04 a
tk
ddendum
t
-w
o
, f
-w
wo
Ire
utdoor
our
Low voltage wiring consists of two wires between the indoor
unit and heat pump and four wires between the indoor unit
and thermostat. The required wires are data lines 1 and 2,
"R" (24 VAC hot) and "C" (24 VAC common).
Never connect the power wiring to communication terminal.
(1, 2, R, C)
<In case of Air Handler>
CTK04
1
2
R C
Thermostat
125 ft.(*)
CT™ Compatible
1
2
R C
Air Handler Blower Integrated
Control Module
250 ft.(*)
CT™ Compatible Heat Pump Integrated
1
2
R C
Control Module
(*) Allowable Maximum Length
System Wiring
<In case of Cased Coil>
CTK04
Thermostat
1
2
R C
(a)
(a)+(b)
CT™ Compatible
=125 ft.(*)
1
2
R C
Gas Furnace or
Modular Blower
Integrated Control Module
250 ft.(*)
CT™ Compatible Heat Pump
1
2
R C
Integrated Control Module
(*) Allowable Maximum Length
System Wiring
ATTEnTion inSTAllEr -
iMPorTAnT noTicE!
Please read carefully before installing this unit.
• For DZ17VSA, do NOT install the 24 Volt Transformer
that is included with the cTK04 Thermostat.
• Do not attach any wires to the R & C Terminals on the
Heat Pump, as they are not needed for inverter unit.
• Data line terminal #1 from heat pump must connect to
terminal #1 on indoor unit and thermostat and data line
terminal #2 from heat pump must connect to terminal
#2 on indoor unit and thermostat. Verify wires are not
reversed.
I
w
Ire
ndoor
IrIng
(b)
1
2
R C
CT™ Compatible
Cased Coil
Integrated
Control Module
43
43

Publicité

Table des Matières
loading

Table des Matières