Please read this instruction manual carefully before use and for further information on the
individual functions.
Danger:
• Never use this unit in combination with the following medical electronic devices.
(1) Medical electronic implants such as pacemakers.
(3) Portable electronic medical devices such as electrocardiograph.
• This unit may cause the above-mentioned medical electronic devices to malfunction, posing a
considerable health risk to users of these devices.
Warning:
• Never start weight reduction or exercise therapy solely based on your own judgement. Be sure
to follow the instructions of a doctor or specialist.
• Do not jump or bounce on the unit.
• Do not use this unit after taking a bath, or when your body, hands, or feet are wet.
• Do not step on the edge of the unit.
• Do not let a physically handicapped person use this unit without any accompanied assistance.
Use a handrail or so when stepping on the unit.
• When the device malfunctions, it may get hot.
Areas with a possible rise in temperature:
(1) Around the battery compartment area: 105°C (max.)
(2) The electrodes and operation buttons: 48°C (max.)
If the device malfunctions and does not operate, stop using it immediately.
Do not apply the electrodes or keep touching the operation buttons for 10 minutes or more.
Caution:
• This unit is intended for home use only. It is not intended for professional use in hospitals or
other medical facilities.
• This unit does not support the standards required for professional use.
• Stand on the unit bare-footed.
• During measurement, make sure that no mobile phone or any other electrical devices that emit
device and/or cause an inaccurate reading.
Troubleshooting
If the problem persists, please refer to the table below.
Error Display
Possible cause
You step off the unit during the measurement.
Your feet are not correctly positioned on the electrodes.
The measurement position is not stable or your feet are not
placed correctly.
Feet are too dry.
The unit is not set up correctly.
You step onto the unit before 0.0 kg (0.0 lb) is displayed.
The unit moved before 0.0 kg (0.0 lb) is displayed.
Movement during measurement.
Your weight is over 150.0 kg (330.0 lb or 23 st 8.0 lb).
Technical Data
Product Category
Product Description
Model (Code)
Display
Set Items Personal data information:
Weight Accuracy
Accuracy (S.E.E.)
Durable Period
Power Supply
Battery Life
Operating Temperature / Humidity /
Storage and Transport Temperature /
Humidity / Air Pressure
Protection Against Electric Shock
Applied Part
Weight
External Dimensions
Package Contents
Please report to the manufacturer and the competent authority of the Member State in which you are established about any serious incident that has occurred in relation to this device.
Correction
Do not step off the unit till the measurement is completed.
Make sure that you are standing on the unit correctly and try again.
Remain still and do not move during measurement.
Slightly moisten the soles of your feet with a damp towel and try again.
Remove the batteries. Wait one minute. Reinstall the batteries. Touch the ON-OFF-SET button and turn on the
power. Retake the measurement.
Wait until 0.0 kg (0.0 lb) is displayed before stepping onto the unit.
Do not move the unit until 0.0 kg (0.0 lb) is displayed
Do not move till measurement is completed.
This unit can only be used by people weighing less than 150.0 kg (330.0 lb or 23 st 8.0 lb).
Body Composition Analyzers
Body Composition Monitor
BF212 (HBF-212-EW)
Body Weight: 2 to 150 kg with an increment of 0.1 kg / 4.4 to 330.0 lb with an increment of 0.2 lb / 4.4 lb to 23 st 8.0 lb with an increment of 0.2 lb
Body Fat percentage: 5.0 to 60.0% with an increment of 0.1%
BMI: 7.0 to 90.0 with an increment of 0.1
The following information for up to 4 people can be stored.
Height: 100.0 to 199.5 cm , 3'4" to 6'6 3/4" (increment of 1/4")
Age: 10 to 80 years old
Gender: Male/Female
2.0 kg to 40.0 kg: ± 0.4 kg, 40.0 kg to 150.0 kg: ± 1% / 4.4 lb to 88.2 lb: ± 0.88 lb, 88.2 lb to 330.0 lb: ± 1% /
4.4 lb to 6 st 4.2 lb: ± 0.88 lb, 6 st 4.2 lb to 23 st 8.0 lb: ± 1%
Body Fat percentage: 3.5%
5 years
4 AAA batteries (R03) (You may also use AAA alkaline batteries (LR03).)
Approximately one year (When AAA manganese batteries are used with four measurements a day at a room temperature of 23°C.)
-20 to 60°C / 10 to 95% RH (non-condensing) / 700 to 1060 hPa
Internally powered ME equipment
Type BF (Foot Electrodes)
Approximately 1.3 kg (including batteries)
Approximately 285 (W) × 28 (H) × 210 (D) mm
Body composition monitor, 4 AAA manganese batteries (R03), instruction manual
• Do not disassemble, repair, or remodel the unit.
the wrong direction.
• Replace worn batteries with new ones immediately.
• Remove the batteries from this unit when you are not going to use it for a long period of time
(approximately three months or more).
• Do not use batteries of a different kind together.
• Do not use new and worn batteries together.
• Keep this unit out of the reach of young children. Contains small parts that may cause a choking
hazard if swallowed by infants.
General Advice:
measurement may not be possible.
• Do not step on the operation buttons. Doing so may cause malfunction.
• Do not place this unit in highly humid environment, where water may splash, under direct
• Do not use this unit for purposes other than measuring body weight and body fat percentage.
• Disposal of this product and used batteries should be carried out in accordance with the
national regulations for the disposal of electronic products.
• Always keep the unit clean before use.
• Clean the scale before using the unit with people who have a skin or foot disease.
• Do not wash the unit with water.
• Do not wipe the unit with benzene or paint thinner.
• When cleaning the unit, take care not to touch the buttons and change or delete the personal data.
• If storing the unit in a vertical position, always secure it so that it will not fall over.
• Do not store the unit in the following conditions:
- Where water may get in.
- Extreme high temperature and humidity, direct sunshine, and dusty places.
- Where there will be sudden shock or vibration.
- In storage places of chemicals or where corrosive gas is present.
• Do not place objects on the unit or store it upside-down.
• Use the battery within recommended period mentioned to it.