Télécharger Imprimer la page

Miele MF01 10 Notice De Montage page 6

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 9
Produktgruppe 512
6 von 38
Den Deckel der Maschine anbauen.
Elektrische Sicherheitsprüfung durchführen.
Die Maschine an dem bestimmungsgemäßen Elektroanschluss anschließen.
de
en
Parts required
Quantity
Mat. no.
1
09079440
1
09079450
1
09079460
1
09079470
Dispenser pumps
and accessories:
1
05573160
1
05571620
1
05572530
1
04814240
Note
This service and repair work should only be carried out by a suitably qualified electrician (with specialist training, knowledge and
experience, and recent related work experience) in accordance with all appropriate local and national safety regulations.
Servicing, modification, testing and maintenance of electrical appliances should only be carried out in accordance with all appropriate
legal requirements, accident prevention regulations and valid standards. All regulations of the appropriate utility supply companies and
standards relating to safety (not limited to electrical safety) are to be complied with.
Note
Service and repair work on gas machines should only be carried out by suitably qualified persons in accordance with all appropriate local
and national safety regulations. Ensure all special regulations applying to gas installations are also complied with.
Before any service work is commenced, the machine must be disconnected from the gas mains.
Danger!
Even with the machine switched off, mains voltage may be applied to some components.
Before any service work is commenced, the machine must be disconnected from the mains. Suitable measurements must be made to
ensure that this is the case.
A general visual check and risk evaluation should always be carried out.
Incorrect conversion or service work can be dangerous (risk of fire, electric shock, etc.).
Danger!
Correct earthing function can be deactivated if casing parts are incorrectly assembled.
Correct earthing function must be ensured when refitting the casing.
Carry out appropriate electrical safety checks.
09.08.2011
Diese Unterlagen dürfen ohne unsere Genehmigung weder vervielfältigt noch Dritten zugänglich gemacht werden. Eigentumsrechte vorbehalten.
Umbau- und Montageanweisung
Designation
Fitting kit - MF01 10-20 multifunction module PW 6xx7, liquid dispensing 1 - 6
Fitting kit - MF02 10-20 multifunction module PW 6xx7, liquid dispensing 7 - 12
Fitting kit - MF03 10-20 multifunction module PW 6xx7, liquid dispensing 7 - 11
and water recycling (WRG)
Fitting kit - MF05 10-20 multifunction module PW 6xx7, liquid dispensing 1 - 3 and
water recycling (WRG)
DOS-P2 dispenser pump
DOS-R non-return valve
DOS-G2 dispenser pump housing for maximal 3 dispenser pumps
DOS-S dispenser pump stand for maximal 3 dispenser pumps
M.-Nr. 09149680