Troubleshooting
Although the DTRXDC receiver is characterized by a great ease of use, sometimes troubles may occur, especially
during the installation and configuration phases or using the unit..
Led LD8 is off
Led LD8 is on.
The instruction are not
executed
The Pan & Tilt does not
work
The lens does not work
In a cascade connection,
the units which follow do
not receive the user's
commands
No power supplied to the unit
The fuse is blown
Wrong configuration of the reception
Wrong connection
Wrong DTRXDC identification
Wrong speed
The unit is blocked
Wrong connection of Pan & Tilt
Wrong lens voltage
Wrong connection of lens
Wrong connection
Wrong configuration of the reception
Wrong speed
Check the power cord
Replace the F1 fuse
Control the JP1 jumper
Check the connecting cables
Control the DTRXDC identification number
Check the position of switches 6 and 7 of
dip-switch SW2
Press the BP1 reset button or turn off the
power
Check the connection cables of Pan & Tilt
Check the connection cables of lens
Control the adjustment of the TR1 trimmer
Check the connetion cables
Check the jumper JP1
Check the position of switches 6 and 7 of
dip-switch SW2
Page. 13
MNVCDTRXDC_1511_EN