Automatic temperature control
To guarantee safe operation, the spotlight continuously reduces both power consumption and light intensity as son as
the permissible maximum temperature value is reached.
Set-up and start-up
The unit is supplied without a transformer. When set up above the water level, maintain a safety distance of at least 50
cm from combustible material. Ensure a safe seating. Do not cover the unit. Danger of fire! A swivel bracket (4) can be
fitted to the spotlight by means of a screw connection. Position the unit such that it does not present a hazard for any-
body. When fitting in the pond, fasten the unit on a suitable base by means of the swivel bracket. The ground stake
(5+6) can be used when installing the unit out of the water. Connect the power plug of the spotlight to the socket of the
transformer bush (2+3). Connect the transformer to the power supply. Check the spotlight function.
The spotlight can be operated with 12 VAC or 24 VDC (no dimmer function). 12 VAC or 24 VDC (above water level) 12
VAC (below water level).
Adhere to the attached information sheet about the connection of existing transformers and cables with regard to the
seal.
Replacing the bulb (1)
Adhere to the safety instructions! Disconnect the power! Undo the screw-connection of the top section. Ensure that no
moisture can enter the unit. Remove and clean the top and the glass. Disconnect the plug connector and (open the
large bracket on the flat side of the plug) remove the bulb. Important! Only original bulbs from OASE may be used. In-
sert the new bulb. Note that the recess at the outside of the retaining ring is inserted via the housing web. Check the O-
ring and replace, if damaged. Reassemble the unit in the reverse order, connect to the power supply and perform a
function check.
Wearing parts
Bulbs are wearing parts and are excluded from the warranty.
Spare parts
The use of original parts from OASE ensures continued
safe and reliable operation of the unit.
Please visit our website for spare parts drawings and spare
parts.
Cleaning
Adhere to the safety instructions! Carry out the work steps as specified under 'Replacing the bulbs'. Only use water
and a soft brush. Ensure that no moisture can enter the unit.
Note
Do not dispose of this unit with domestic waste.
• Render the unit unusable beforehand by cutting the cables and dispose of the unit via the return system provided
for this purpose.
S
Malfunctions
Malfunction
Lamp does not light up
Light intensity decreases
Water in the spotlight housing
www.oase-livingwater.com/spareparts
Cause
Power supply interrupted
Bulb defective
Lamp glass soiled
Seal defective
Remedy
Check power supply
Replace bulb
Clean
Check sealing rings and replace, if necessary