Technical Data; Before Starting The Equipment; Electrical Safety; Environmental Protection - HERKULES SE 5000 DF Mode D'emploi D'origine

Masquer les pouces Voir aussi pour SE 5000 DF:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 19
Anleitung_SE_5000_DF_SPK7:_
GB

5. Technical data

Generator
Protection type
Continuous power S1 4200 W/400 V; 3000 W/230 V
Maximum power S2 (max. 5 min)
5000W/400 V; 3300 W/230 V
Continuous power S1 (12 V d.c.)
Rated voltage
2x 230V~/1x 400V~/1x 12V d. c.
Rated current
13 A (230V~) / 6.1 A (400V 3~)
Frequency
Displacement
Motor rating
Fuel
Tank capacity
Engine oil:
Weight
Sound pressure level L
:
pA
Sound power level L
:
WA
K uncertainty
Power factor cos ϕ:
Power class:
Max. altitude (above mean sea level):
Operating mode S1 (continuous operation)
The machine can be continuously operated with the
quoted power output.
Operating mode S2 (temporary operation)
The machine may be temporarily operated with the
quoted power output. Afterwards the machine must
be stopped for a while to prevent it from overheating.
14
18.04.2011
10:37 Uhr
Seite 14

6. Before starting the equipment

Important. The equipment must be filled with engine
Synchronous
oil and diesel fuel before it is started.
IP 23
Prepare and connect the battery (Important. The
battery is not included.) Secure the battery (Fig.
4/Item A) in the unit using the battery mounting kit
(Fig. 3/Item 20). First connect the red cable (+)
and then the black cable (-) to the battery.
100 W
Check the diesel fuel level and top it up if
necessary.
Make sure that the device has sufficient
ventilation.
50Hz
Inspect the immediate vicinity of the generator.
418 ccm
Disconnect any electrical equipment which may
6.3 kW / (8.6 hp)
already be connected to the generator.
Diesel

6.1 Electrical safety:

16 liters
Electric supply cables and connected equipment
1.65 l (15W40)
must be in perfect condition.
165 kg
The generator is to be operated only with
76 dB(A)
equipment whose voltage specifications conform
with the generator's output voltage.
96 dB (A)
Never connect the generator to the power supply
1 dB
(socket-outlet).
1
Keep the cable length to the consumer as short
G1
as possible.
1000 m

6.2 Environmental protection

Dispose of soiled maintenance material and
operating materials at the appropriate collection
point.
Recycle packaging material, metal and plastics.

6.3 Connecting to earth

The housing is allowed to be connected to earth in
order to discharge static electricity. To do this,
connect one end of a cable to the earth connection
on the generator (Fig. 2/Item 14) and the other end
to an external earth (for example an earthing rod).

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

41.523.51

Table des Matières