Balluff BML-S1G0 Serie Notice D'utilisation D'origine page 57

Système de mesure de déplacement à codage magnétique absolu
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

BML-S1G0-_7_ _-M5E_-_0-_ _
Absolute Magnetically Coded Position Measuring System
7
Diagnose (continued)
7.2
Transferring the diagnostic data,
SSI interface
These data are only sent after enabling the BML
Configuration Tool (section 10.5).
7.2.1
Standard SSI and BEF
Fig. 7-5 shows the time relationships for optional
diagnostic data transmission. The controller now outputs
n+8 clock periods instead of n clock periods up to t2, as
for standard SSI transmission. The BML transfers the
normal data between t1 and t2, beginning with the error
and the null, and then continuing with the MSB through to
the LSB (see section 6.1 on page 16). With the 8
additional clock periods, the BML transfers the diagnostic
data, starting with the diag MSB through to the diag LSB.
After all data has been received in the controller at time t3,
the position value and exactness factor are determined in
the controller.
Clk
BiSS Data
E
Null
t1
Fig. 7-5:
SSI signals (position and BEF)
If the controller only transmits clock impulses up to t2, the
received data is compatible with the standard SSI interface
from section 6.1 on page 16.
7.2.2
Standard SSI, BEF, and error bits
If the control outputs 8 additional clock periods as in
Fig. 7-6 8 additional error bits are output following the 8
diagnosis bits, as per section 8 on page 25.
Clk
BiSS Data
E
Null
t1
Fig. 7-6:
SSI signals with BEF and error bits
Up to time t2, the position is transmitted, up to t3 the 8-bit
diagnostic value, and up to t4 the error bits.
www.balluff.com
Diag
MSB
LSB
MSB
t2
MSB
LSB
t2
Diag
t m
LSB
t3
Diag
ERR
ERR
t m
LSB
MSB
LSB
t3
t4
english
t
t
t
t
t
t
23