Safety Functions - Rommelsbacher WP 250 Guide De L'utilisateur

Masquer les pouces Voir aussi pour WP 250:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

between the recesses.
Please lay the enclosed sealing-tape on-end on the outermost border of the recess, then press on the
appliance from the top.
Under the galvanised bottom plate there are 4 rectangular gaps for mounting clamps.
If the tabletop has a thickness of 3 cm, the clamps should be fastened according to illustration C. If the
thickness is 4 cm, please fix the clamps according to illustration B.
Finally tighten the screws on the clamps to fix the tray.
The appliance comes delivered with a power cord equipped with a safety plug. Please provide for a fuse
protection of at least 10 ampere.
Touch Control
This model is equipped with Touch Control sensors which allow for easy and highly convenient operation.
By lightly pressing the main button (POWER symbol), the appliance is switched on. The '0' flashing up
in the 7-segment display above the +/- symbols shows you that the unit is switched on. By touching the
POWER sensor once more, the appliance is switched off again.
You may select the temperature by touching the field marked with the + and - symbols.
Touching the + sensor for the first time, the appliance gets started at level 1. You may increase the setting
up to level 9 by touching the + sensor repeatedly. If this sensor is activated permanently, the display
changes at intervals of 0.5 seconds.
If the – sensor is touched for the first time, the appliance gets started at level 9. Going on touching it you
may reduce it down to level 1. If this sensor is activated permanently, the display changes at intervals of
0.5 seconds too.
The hot tray is equipped with an automatic heating system. If this shall be used, heat level 9 has to be
activated with the – sensor. Beside the display indicating heat level 9, an additional point becomes visible.
This shows that the automatic heating system has been triggered.
If the heat level is reduced within 10 seconds by means of the – sensor, the automatic heating system
remains activated for all settings. As long as the automatic heating system is on, the hot tray is operated
with maximum power during the initial heating period, which is in return dependent on the heat level
selected. Once the automatic heating peak is over, the luminous point will go out and the hot tray has
reached the desired temperature.

Safety functions

The Touch Control technology features several safety functions so as to prevent any unintentional
activation.
If you do not trigger any further functions within 10 seconds after the appliance has been switched
on, the hot tray will automatically switch off again.
Beyond that, its electronics detects whether the sensors are touched purposefully. If you place a kit-
chen towel or similar on the appliance, it will not get triggered. The same goes for liquids that might
run over the glass surface.
The safety switch-off will also get triggered if one or several sensors are activated for more than 12
seconds. In this case the control system switches off the hot tray. In the heat level display, an 'F' flas-
hes up. In this case, please switch off the appliance completely via the POWER sensor and start the
keep warm procedure anew.
When the appliance is switched on, the sensors adjust themselves automatically to the environmental
conditions. During that adjustment the glass surface above the sensors must not be covered. Only
if it is exposed to extreme external light, or if it is covered with a light object, an adjustment will not
be possible. This will also be indicated through an 'F' in the heat level display. In this case too, please
switch off the appliance completely via the POWER sensor, remove the external light and the cover
respectively and start the keep warm procedure anew.
The temperature settings:
approx. 40° C
1
approx. 60° C
3
5
approx. 75° C
approx. 90° C
7
approx. 105° C
9
5

Publicité