Kobalt XC302000 Manuel D'utilisation page 20

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

TROUBLESHOOTING
PROBLEM
Reset
5. Pressure switch shut-off pressure
mechanism
set too high.
cuts out
6. Low voltage.
repeatedly
or circuit
breaker trips
repeatedly.
(Continued)
7. Malfunctioning check valve.
8. Defective unloader valve on
pressure switch.
9. Defective motor capacitor(s).
10. Malfunctioning motor.
11. Low voltage.
Tank does
1. Air leaks (fittings, tubing on
not hold
compressor, or plumbing outside
pressure
system).
when
2. Worn check valve.
compressor
is off and the
shut off valve
is closed.
3. Check tank for cracks or pin holes. 3. Replace tank. Never repair a damaged tank.
Excessive
1. Loose fasteners on pump or motor. 1. Tighten fasteners.
vibration.
2. Belt needs replaced.
3. Belt alignment.
POSSIBLE CAUSE
CORRECTIVE ACTION
5. Replace pressure switch.
6. Check incoming voltage. It should be
approximately 120 volts. Low voltage could be
due to wires (from breaker/fuse to outlet) being
too small in diameter and / or too long. Have a
qualified electrician check these conditions and
make repairs as needed.
7. Replace check valve.
DANGER
Risk of Explosion. Do not
disassemble check valve with air
pressure in tank.
8. Replace unloader valve.
9.Replace capacitor(s).
10. Replace motor.
11. Check incoming voltage. It should be
approximately 120 volts. Low voltage could be
due to wires (from breaker/fuse to outlet) being
too small in diameter and / or too long. Have a
qualified electrician check these conditions and
make repairs as needed.
1. Check all connections with soap and water
solution. Tighten; or remove and apply sealant
to threads, then reassemble.
2. Replace check valve.
DANGER
Risk of Explosion. Do not
disassemble check valve with air
pressure in tank.
2. Replace with correct size.
3. Align flywheel and pulley.
20

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

0905519

Table des Matières