TROUBLESHOOTING
PROBLEM
Large
1. Worn piston rings.
quantity of
oil in the
2. Compressor air intake restricted.
discharge air
NOTE: In
3. Excessive oil in compressor.
an oil-lubed
4. Wrong oil viscosity.
compressor
there will
always be a
small amount
of oil in the
air stream.
Water in
Normal operation. The amount of
discharge air /
water increases with humid weather.
tank.
Motor hums
1. Low voltage.
and runs
slowly or not
at all.
2. Use of extension cord.
3. Too many devices on same circuit. 3. Limit the circuit to the use of compressor only.
4. Loose electrical connections.
5. Malfunctioning pressure switch -
contacts will not close.
6. Malfunctioning check valve.
7. Defective unloader valve on
pressure switch.
8. Defective motor capacitor(s).
9. Defective motor.
Reset
1. Lack of proper ventilation / room
mechanism
temperature too high.
cuts out
2. Too many devices on same circuit. 2. Limit the circuit to the use of only the air
repeatedly
or circuit
3. Restricted air intake.
breaker trips
4. Loose electrical connection.
repeatedly.
POSSIBLE CAUSE
CORRECTIVE ACTION
1. Replace with new rings. Maintain oil level and
change oil more frequently.
2. Clean or replace filter. Check for other
restrictions in the intake system.
3. Drain down to full level.
4. Use Mobil 1
10W-30 or full synthetic.
®
1. Drain tank more often. At least daily.
2. Add a filter to reduce the amount of water in
the air line.
1. Check incoming voltage. It should be
approximately 120 volts. Low voltage could be
due to wires (from breaker/fuse to outlet) being
too small in diameter and / or too long. Have a
qualified electrician check these conditions and
make repairs as needed.
2. Do not use an extension cord. Use longer air
hose with larger diameter.
4. Check all electrical connections.
5. Replace pressure switch.
6. Replace check valve.
DANGER
Risk of Explosion. Do not
disassemble check valve with air
pressure in tank.
7. Replace unloader valve.
8. Replace capacitor(s).
9. Replace motor.
1. Move compressor to well-ventilated area.
compressor.
3. Clean or replace filter element.
4. Check all electrical connections.
19