Set
During the start-up of the Sentio system you have to choose the type of system (profile) that the Sentio unit has to control.
To make this manual easier to read to most common types are included. All other descriptions you can find at www.wavin.
com/Sentio
By default the Sentio Unit comes with profile 1.1 as active. To change the profile and/or set all parameters a Sentio
commissioning touch screen (VII) or the PC-tool (download via www.wavin.com/Sentio , Sentio Connection Cable for
PC (XIII) required) is needed.
Choose Profile
Commissioning Touch Screen: System | Installer settings | Hardware profile | Change profile*
Heating/cooling source With
District heating
Boiler/Heat pump
Condensing boiler
Heat pump UFH/UFC
Any single source
+ dehumidifier
* see page J
If more than 8 outputs are required, then an extension unit (EU-A) (V) can be added to the system.
Most situations are covered by selecting the right profile, but some settings might have to be set for your specific system:
W hen using a wired thermometer (XV) on input T1 make sure to enable this sensor.
Commissioning Touch Screen: System | Installer settings | Hardware profile | Set outdoor temperature source
R ooms are default controlling on air temperature, for UFH with floor sensors set regulation mode to floor
(or 'air & floor').
Commissioning Touch Screen: Room | Settings | Winter mode | Advanced Settings | Regulation mode
I TC-servo type is by default a 3-points servo motor, for a different type see Technical Handbook.
Commissioning Touch Screen: System | Installer settings | Hardware profile | Configure required inputs and output |
Servos | ITC Servo | Servo type
T
o change a room name go to Info | Room | Settings
6
6
None
1 ITC loop
2 ITC loops
None (On/off control)
0-10V control
0-10V control, 1 ITC loop
0-10V control, 2 ITC loop
Heat/Cooling switch
Automatic switch
1 ITC + Heat/Cooling switch
1 ITC + Automatic switch
2 Heat/cooling circuits
1 ITC
1 ITC + heat/cooling circuit
2 ITC + heat/cooling circuit
Profile
Required
1.0
1.3.1
Inlet sensor, outlet sensor
1.3.2
Inlet sensor, outlet sensor
1.1
1.2
2.2.1
Inlet sensor, outlet sensor
2.2.2
Inlet sensor, outlet sensor
3.3.0
Inlet sensor (recommended)
3.3.1
Outdoor Sensor, Inlet sensor (recommended)
3.3.2
Inlet sensor, outlet sensor
3.3.3
Outdoor Sensor, Inlet sensor, outlet sensor
4.1.1
4.1.2
Inlet sensor, outlet sensor
4.1.3
Inlet sensor, outlet sensor
4.1.4
Inlet sensor, outlet sensor