Connecting to LAN
If you want to be able to control the system via the Sentio
App, the CCU must be connected to your router. This is
done with a standard netcable (RJ45 plug), which is con-
nected to port M at the bottom of the CCU.
Connecting the Commissioning Touch Screen
To get a complete overview of the whole installation and
be able to set up all parameters for the system a commis-
sioning touch screen can be connected. It is connected
with a standard netcable (RJ-45 plug) into port J or L at
the CCU/EU.
Connecting a Smart Radiator Thermostat
After attaching the M28, M30 or RA adapter on the ther-
mostatic valve the Radiator Thermostat(XVI) can be clicked
on. To enroll this component, select a room channel on the
CCU and insert the batteries or use the commissioning tool.
If the Radiator Thermostat (XVI) is in a position where it is
not properly able to measure the room temperature, add
a room Thermostat(I)/Sensor(II) to improve temperature
measurements.
Connecting a Dehumidifier unit
For humidity control and optimized cooling a dehumidifier
can be added to the system via an Extension Unit with
relays (VI). By connecting the dehumidifier connection ("D")
and the thermal integration connection ("TI") according to
Pre-set
Unit
1.1
1 x Dehumidifier (P/S300)
1.2
2 x Dehumidifier (P/S300)
1.3
3 x Dehumidifier (P/S300)
1.4
4 x Dehumidifier (P/S300)
2.1
1 x Dehumidifier with H/C coil (PC/SC300)
2.2
2 x Dehumidifier with H/C coil (PC/SC300)
2.3
3 x Dehumidifier with H/C coil (PC/SC300)
the pre-set sub-profiles as shown in the table below to
enroll all units at once. Wavin can offer dehumidifier units
P300, S300, and dehumidifier units with heating/cooling
coil PC300 and SC300 for this functionality. For more
information on dehumidifier see the Technical Handbook at
www.wavin.com/Sentio.
Limitations
The Sentio system can contain a fixed maximum number of
components. Keep these in mind when designing a system.
Rooms
Thermo Actuators 24V DC 1W
Dehumidifiers
Room Thermostats/Sensors
Outdoor Temperature Sensor
Smart Radiator Thermostat
Extension Unit (EU-A)
Extension Unit with VFR (EU-VFR)
Touch Screen Commissioning tool
Connections to Extension Unit (EU-VFR)
A
B
C
D
D
D
D
D
D
D
D
D
D
TI
D
TI
D
D
TI
D
Max
24
16
4
24
1
16
2
2
2
D
E
F
D
TI
TI
D
TI
5