– if the distance between the wireless microphone
and the active speaker system is too long or if
there are obstacles in the transmission path
which may screen the radio signal.
7) After operation, switch off the active speaker sys -
tem with the POWER switch (1). To switch off the
wireless microphone, set the switch (27) to OFF.
Note: If the active speaker system is operated via
the 230 V mains, it will even have a low
power consumption when it is switched off. To
save energy, disconnect the mains plug from
the mains socket if the unit is not used for a
longer period.

7 Charging Batteries

The active speaker system allows to charge a 9 V bat-
tery (6F22) and up to two 1.2 V batteries of size AA.
Batteries can only be charged in case of mains oper -
ation of the active speaker system.
Caution: Only charge NiCd or NiMH rechargeable
batteries; non-rechargeable batteries may leak or
even explode if you try to charge them!
1) Remove the cover plate on the rear side of the unit.
2) To charge a 9 V battery, connect the poles of the
battery to the snap-on contacts (19), and insert the
battery into the compartment (16) on the right.
To charge batteries of size AA, insert the bat -
teries into the compartment (13) on the left.
Observe the correct position of the positive and
negative poles (→ imprint in the compartment). It is
also possible to charge a single battery: insert the
battery into the left or right side of the compartment.
Note: Each charging compartment is equipped
with a fabric ribbon. When inserting a battery
into a compartment, make sure that the rib-
bon is underneath the battery and that the
end of the ribbon is outside the compart-
ment. This will make it easy to remove the
battery later by pulling the end of the ribbon.
3) Replace the cover plate and switch on the active
speaker system with the POWER switch (1). The
unit can still be used for PA applications while bat-
teries are being charged.
4) During charging, the corresponding charging LED
will light up:
LEDs "AA Size Recharge" (14)
for the left (L) and right (R) battery of size AA
LED "6F22 Recharge" (15)
for the 9 V battery
5) When the corresponding charging LED is extin -
guished, charging is completed. Remove the cover
plate and take out the battery/batteries.
All rights reserved by MONACOR
be reproduced in any form or by any means for any commercial use.
®
INTERNATIONAL GmbH & Co. KG. No part of this instruction manual may
8 Specifications
Output power: . . . . . . . . 20 W max.
2 inputs MIC: . . . . . . . . . 2.5 mV
1 input AUX: . . . . . . . . . 130 mV
1 output REC. OUT: . . . 280 mV/100 kΩ
Tone control: . . . . . . . . . ±5 dB / 10 kHz (treble)
Ambient temperature: . . 0 – 40 °C
Power supply
Active speaker
system: . . . . . . . . . . . 230 V~/50 Hz/40 VA
Wireless microphone: two 1.5 V batteries
Dimensions, weight
Active speaker
system: . . . . . . . . . . . 220 × 275 × 140 mm, 3.3 kg
Wireless microphone: ∅ 48 × 235 mm, 165 g
Accessory supplied: . . . 1 shoulder bag

8.1 Radio transmission

Radio frequency range: . 863.05 – 864.95 MHz
Audio frequency range: . 50 – 15 000 Hz
Transmitting power
of microphone: . . . . . . . < 10 mW (EIRP)
Range: . . . . . . . . . . . . . approx. 30 m (depending on
Channel assignment
Channel
Frequency
0
863.05 MHz
1
863.25 MHz
2
863.55 MHz
3
863.75 MHz
4
864.05 MHz
Subject to technical modification.
±4 dB / 200 Hz (bass)
or 12 – 15 V /1 A
or eight 1.5 V batteries of
size D
(or two 1.2 V rechargeable
batteries) of size AA
(→ table below)
local conditions)
Channel
Frequency
5
864.25 MHz
6
864.55 MHz
7
864.75 MHz
8 – F
864.95 MHz
GB