Display
Description
STG1
Operation of the G1 terminal. Choose between the following values:
G1-SETTING
NO = no function
KO = opening command 1 - G1
KC = closing command 1 - G1
VOPN = N.O. opening limit-switch 1 - G1
STEP = Step-by-step contact N.O. The closing of the 1-G1 contact performs in sequence the opening
(disabled automatic closure) and the closing of the door.
SAM = Automatic setting command of function selector. The closing of the 1-G1 contact changes the
function selector mode (see menu: SEL > SAM1 and SEL > SAM2).
EMER = Emergency opening contact N.C. The opening of the 1-G1 contact opens the door.
RSET = reset command 1 – G1
CAB = Step-by-step contact N.O. The closing of the 1-G1 contact performs in sequence the closing of
the door (disabling 3A/3B terminals, enabling the signaling for occupied cabin) and the opening of the
door (enabling 3A/3B terminals, disabling the signaling for occupied cabin).
BELL = Output 0-G1 (12Vdc 20mA). The output is activated for 3 seconds when people enter the store
(through the sequential activation of the contacts: 1-3B and 1-3A).
SIGN = Output 0-G1 (12Vdc 20mA). The output is activated when the door is in the closed or opening
position (see menu: ADV > SIGN).
SERV = Output 0-G1 (12Vdc 20mA). The output is activated when the door reaches the number of
maintenance cycles, set using the menu: INFO> SERV.
WARN = Output 0-G1 (12Vdc 20mA). The output is activated when at least one warning remains
active for 5 minutes. For remove the alarm signal make a reset or turn off the power supply.
STG2
Operation of the G1 terminal. Choose between the following values:
G2-SETTING
NO = no function
KO = opening command 1 – G2
KC = closing command 1 – G2
VOPN = N.O. opening limit-switch 1 – G2
STEP = Step-by-step contact N.O. The closing of the 1-G2 contact performs in sequence the opening
(disabled automatic closure) and the closing of the door.
SAM = Automatic setting command of function selector. The closing of the 1-G2 contact changes the
function selector mode (see menu: SEL > SAM1 and SEL > SAM2).
EMER = Emergency opening contact N.C. The opening of the 1-G2 contact opens the door.
RSET = reset command 1 – G2
CAB = Step-by-step contact N.O. The closing of the 1-G2 contact performs in sequence the closing of
the door (disabling 3A/3B terminals, enabling the signaling for occupied cabin) and the opening of the
door (enabling 3A/3B terminals, disabling the signaling for occupied cabin).
SIGN
Door position indication through the 0-G1 output (see menu: ADV > STG1 > SIGN). Choose between
DOOR
the following values:
POSITION
CLOS = closed door
SIGNAL
OPEN = open door
AIR = door not closed
LAMP = moving door
signaling of the occupied cabin
CAB =
T41
Enable test for safety devices (in accordance with EN 16005). Choose between the following values:
SAFETY TEST
NO = test disabled
YES = test enable
FA00008-EN v.7 – 05/2017
(see menu: ADV > STG2 > CAB)
26

Factory settings

NO
NO
CLOS
YES