Connect Electricity

WARNING
Do not use an extension cord or an adapter plug with
this appliance.
The water heater must be electrically grounded in
accordance with local codes and ordinances or, in the
absence of local codes, in accordance with the
National Electrical Code, ANSI/NFPA No. 70.
Do not rely on the gas or water piping to ground the
water heater. A screw is provided in the junction box
for the grounding connection.
The water heater requires 120 VAC, 60 Hz power from
a properly grounded circuit.
A disconnect switch must be provided and installed
for the incoming 120 VAC power. It should be a type
that is suitable for outdoor use. Check the National
Electrical Code, ANSI/NFPA 70 and your local codes
for a proper switch type to use in your area.
The wiring diagram is located on the Technical Sheet
attached to the inside of the front cover.

Adjust for High Altitude

On the SW1 DIP switch (tan switches), set switches 2
and 3 to the values shown in table below for your
altitude. The default setting for the appliance is 0-
2000 ft (0-610 m) with switches No. 2 and No. 3 in the
OFF position.
When the DIP switch is adjusted, it is not necessary to
adjust the gas pressure setting for high altitude.
Altitude
0-2000 ft (0-610 m)
2001-5200 ft (610-1585 m)
5201-7700 ft (1585-2347 m)
7701-10200 ft (2347-3109 m)

Checklist for Gas and Electricity

A manual gas control valve is placed in the gas
line to the water heater.
Check the gas lines and connections for leaks.
Confirm that the gas inlet pressure is within
limits.
Confirm that the water heater is rated for the gas
type supplied.
Confirm that the electricity is supplied from 120
VAC, 60 Hz power source and is in a properly
grounded circuit.
An extension cord or an adapter plug has not
been used with the water heater.
V53e Manual
SW1
SW1
Switch
Switch
No. 2
No. 3
OFF
OFF
OFF
ON
ON
OFF
ON
ON
13