Faber Maestrale Manuel D'installation page 4

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

CAUTION
To reduce risk of fire and to properly exhaust
air, be sure to duct the air outside – Do not vent
exhaust air into spaces within walls or ceilings
or into attics, crawl spaces, or garages.
TOOLS NEEDED FOR INSTALLATION
• Saber Saw or Jig Saw
• Drill
• 1 1/4" Wood Drill Bit
• Pliers
• Phillips Screwdriver
• Flat Blade Screwdriver
• Wire Stripper or Utility Knife
• Metal Snips
• Measuring Tape or Ruler
• Level
• Pencil
• Caulking Gun
• Duct Tape
PARTS SUPPLIED FOR INSTALLATION
• 1 Hardware Package
• 1 Literature Package
PARTS NEEDED FOR INSTALLATION
• 2 Conduit Connectors
• Power Supply Cable
• 1 Wall or Roof Cap
• All Metal Ductwork
WARNING
!
PERSONAL INJURY HAZARD
Because of the weight and size
of the rangehood canopy, two
or more people are needed
to move and safely install the
rangehood canopy.
Failure to properly lift rangehood
could result in damage to the
product or personal injury.
CALCULATE THE DUCTRUN LENGTH
The ductrun should not exceed 50 equivalent feet
if ducted with the required minimum of 6" round
ductwork (TWO - 6" ROUND DUCTS FOR 48"
MODEL - 75 equivalent feet for 1200
cfm model). Calculate the length of the ductwork
by adding the equivalent feet in FIGURE 1 for
each piece of duct in the system An example
is given in FIGURE 2.
For best results, use no more than three 90°
elbows. Make sure that there is a minimum of
24" of straight duct between elbows if more
than one is used. Do not install two elbows
together. If you must elbow right away, do it
as far away from the hood's exhaust opening
as possible.
WARNING! BEFORE MAKING ANY CUTS OR HOLES FOR INSTALLATION,
DETERMINE WHICH VENTING METHOD WILL BE USED AND CAREFULLY
CALCULATE ALL MEASUREMENTS.
Parts supplied in range hood package:
Remove parts from packages. Check that all parts are included.
• 2 metal grease filters for 30" (76.2 cm) models
• 3 metal grease filters for 36" (91.4 cm) models
• 3 metal grease filters for 42" (106.7 cm) models
• 4 metal grease filters for 48" (121.9 cm) models
• 2 mounting brackets with adjustment screws installed
• 2 mounting bracket screws
• 4 washer head Phillips mounting screws
• Damper
• 2 dampers for 48" (121.9 cm) model.
OPTIONAL FULL WIDTH DUCT COVER
45˚ Elbow
90˚ Elbow
90˚ Flat Elbow
Wall Cap
FIGURE 1
9 Feet Straight Duct
2 - 90˚ Elbows
Wall Cap
Total System
FIGURE 2
PLAN THE INSTALLATION
PRODUCT DIMENSIONS
OPTIONAL TELESCOPIC CHIMNEY
10" DUCT TRANSITION
3.0 feet
5.0 feet
12.0 feet
0.0 feet
9.0 feet
10.0 feet
0.0 feet
19.0 feet
Version 09/12- Page 4