Application

The patented Komet Inverter allows to operate the gun
in two completely independent sector angles. Starting in
sector 1, the gun turns automatically into sector 2 after
a preset time has elapsed. The required time will be set
through a timer.
The timer is fitted with an accelerometer. After the time is
set, and the timer has been activated, the timer remains in
stand-by mode for 36 hours. Within this time frame the gun
can be started. As soon as water is running through the gun,
The Komet Inverter is suitable for the following applications:
Application "A"
Irrigation with initial inversion
of the gun.
8
8
hence the timer triggered through motion, the preset time
starts the countdown.
After the 36 hours have elapsed, the timer must be re-
activated.
If required, a supplied full-circle adapter can be installed.
This allows the gun to change from sector 1 into full-circle
operation mode "C", after the preset time has elapsed. The
full-circle mode remains active, until the adapter is manually
removed.
Application "B"
Irrigation with regular
retraction of the gun.
Application "C"
Irrigation with initial inversion
and transition to full-circle
operation until the end of the
irrigation action.