P
Q
B
ROGRAMMING THE
UIK
RIDGE
Table 7 displays the 17 locations that can be programmed on the Quik
®
Bridge
.
®
Table 7: Quik Bridge
output locations and segments
L
o
a c
o i t
n
S
g e
m
e
t n
0
1-4
1
1
2
2
1
2
3
1
2
4
1
2
5
1
2
6
1
2
7
1
2
8
1
2
9
1
2
10
1
2
11
1
2
12
1
2
13
1
2
14
1
2
15
1
2
16
1
2
17
1
Output event
Enter the number for the event that you wish to program for the output.
Table 8: Quik Bridge
®
output events
D
a
a t
E
e v
t n
0
Zone Open
1
Zone Tamper
2
TX Low Battery
3
TX Lost
4
TX short supervision fault
5
Clean me fault
6
Zone open or tamper (default value)
7
TX lost or low battery
8
TX lost, low battery or tamper
9
Zone open, TX Lost, low battery or tamper
10
Keyfob disarm
11
Keyfob arm
12
Keyfob arm or disarm
13
Keyfob arm stay
14
Keyfob exit
15
Fob fire
16
Fob Medical
17
Keyfob panic
18
Keyfob aux 1 (Option 4 from 'Using the 4 button keyfob)
19
Keyfob aux 2 (Option 5 from 'Using the 4 button keyfob)
20
Receiver Jam
21
Box tamper (receiver or Quik Bridge
22
Receiver communication trouble
®
D
s e
r c
p i
o i t
n
Programming code
Output 1 event
Output 1 time
Output 1 Transmitter selection
Output 1 Special Setting
Output 2 event
Output 2 Time
Output 2 Transmitter selection
Output 2 Special Setting
Output 3 event
Output 3 time
Output 3 Transmitter selection
Output 3 Special Setting
Output 4 event
Output 4 time
Output 4 Transmitter selection
Output 4 Special Setting
Output 5 event
Output 5 time
Output 5 Transmitter selection
Output 5 Special Setting
Output 6 event
Output 6 time
Output 6 Transmitter selection
Output 6 Special Setting
Output 7 event
Output 7 time
Output 7 Transmitter selection
Output 7 Special Setting
Output 8 event
Output 8 time
Output 8 Transmitter selection
Output 8 Special Setting
On if Quik Bridge
®
tamper is enabled
®
)
23
Receiver communication trouble, box tamper or jam
24
Reserved
25
Reserved
Output time
This can be set from 0-255 in minutes or seconds. The unit is set in the
Special Setting segment.
Special Setting
This can be set in the different bits of the segment.
Bit 1: selection of time in seconds or minutes.
•
Turn bit 1 on to time the output in minutes.
•
Turn bit 1 off to time the output in seconds.
Bit 2: selection of inverted output.
•
Turn bit 2 on to invert output activation.
•
Turn bit 2 off for normal output activation.
Important: After the walk test mode times out, the detector returns to
normal operating mode. In normal operating mode, the wireless PIR only
supervises every 2 minutes and the LED is disabled to reduce battery
consumption.
Transmitter Selection
Each bit of the segment corresponds with an output that should be
activated. Each transmitter can be set to activate 1, several or every out-
put. Turn the corresponding bit of the segment on if the transmitter should
activate the output.
Table 8: Quik Bridge
®
output events
E
x
a
m
p
e l
o T
e s
t t
a r
s n
m
t t i
r e
1
o t
a
i t c
a v
o l (
a c
o i t
n
2
e s
g
m
e
t n
) 1
o T
e s
t t
a r
s n
i m
e t t
s r
2
a
d n
8
2
o l (
a c
o i t
n
4
e s
g
m
e
t n
) 1
o T
s
t e
l a
8 l
t
a r
s n
m
e t t
s r
o t
a
o l (
a c
o i t
n
1
6
e s
g
m
e
t n
) 1
C
Q
B
ONNECTING THE
UIK
®
The Quik Bridge
is compatible with any control panel via 8 open collector
outputs. After you have enrolled the transmitters and programmed the Quik
Bridge
®
, you MUST disconnect the CSX75 LCD keypad from the Quik Bridge
and the Receiver. You should then connect the Quik Bridge
zones 1-8 on the panel are programmed to match the programming of the
outputs on the Quik Bridge
®
Connect the Quik Bridge
®
outputs to the zone inputs on the control panel.
There are 4 ways to wire the loop receiver to the control panel. Refer to
Figures J1 through J4 for panel connections.
P
ROGRAMMING THE PANEL
Please refer to the panel's instruction manual to see the steps for program-
ming the inputs.
You must ensure that the programming of the panel inputs matches the
programming of the output events on the Quik Bridge
is no point programming an output event as 5 (Clean me fault), if there is
not an equivalent zone type on the panel.
S
PECIFICATIONS
Compatibility:
Housing:
Receiver:
Power Requirements:
Current Draw:
Open Collector Outputs (1-8, B, S):
maximum sink current 50 mA (typical) 15 mA (minimum)
Temperature Range:
Dimensions:
7
S
e
t t
n i
g
e t
o
u
p t
t u
1
- 1
- -
- -
- -
o t
a
i t c
a v
e t
o
u
p t
t u
2 -
-
- -
- -
8
i t c
a v
e t
o
u
p t
t u
8
1
2
3
4
5
6
®
RIDGE
TO THE PANEL
.
®
. For example there
Control panels with hardwire loops.
maximum applied voltage 16 VDC
10.31 x 13.13 x 2.5 cm (L x W x H
7
8
®
®
to ensure that
RXWEH00
RX8W8CA-Pcb
10 – 14 VDC
60 mA maximum
-10°C to +40°C