OPERATION ALL MODLES

Lighting Standing Pilots - All Models

These units are not designed to be disconnected from
their gas connections and re-installed on a regular basis.
Quick connect gas lines should not be used. Once the gas
appliance has been installed by a licensed gas trades-person
all connections, pilot lights and controls have been inspected
for proper operation. All gas appliances that use standing
pilot systems are generally assumed to be operating with
the pilot on continuously. The units should not be restarted
except in the event of a gas service interruption to the
facility.
If a pilot flame does go out, here are the basic steps to check
before you re-light the pilot:
1. Check to see that all gas lines are in place and secured
and that there is no accumulation of gas inside the unit.
2. Check to make sure that the main shut off valve is in the
off position.
3. Turn the thermostat to the off position. (If applicable)
4. Turn on or open the main shut off valve to the appliance.

MAINTENANCE INSTRUCTIONS

NOTE: Any maintenance or service involving disassembly
of components should be made by a qualified service
technician. Also, ensure gas supply to the appliance is shut
off.
You have purchased the finest commercial cooking
equipment available anywhere. Like any other fine precision
built piece of equipment, it should be given regular care and
maintenance.
Periodical inspections by your dealer or qualified service
agency are recommended to check temperatures,
adjustments and ensure moving parts are operative.
Whenever possible, avoid overheating idle equipment as this
is the primary cause for increased service costs.
Page 12
5. Depending on the appliance type:
Lower the front black enamel panel to the unit and
immediately depress the red button, which is the
piezo to ignite the pilot.
Or.
Remove the front valve panel and light the pilot
with a lighted taper, through pilot viewing hole.
6. The pilot should ignite within a few attempts. You will be
able to see the pilot flame through the observation hole
in the stainless steel front panel.
7. If you do not have a pilot flame established fairly quickly
and begin to smell gas, shut off the main valve and wait
five minutes to let the gas build-up escape.
8. Only once the pilot flame has been established should
you turn on the burner control. When the burner control
is on it allows gas flow to the burner. If there is no pilot
flame it will allow gas to build up and cause possible
delayed ignition, which could result in an explosion.
When corresponding with the factory or your equipment
dealer regarding service problems or replacement parts,
be sure to refer to the particular unit by the correct model
number (including prefix and suffix letters and numbers) and
the serial or code number. The rating plate affixed to the unit
contains this information.
"Regular Maintenance Ensures Peak Performance."

Cleaning Instructions

Black Baked Enamel – Allow equipment to cool after use
and wash all grease deposits from exterior with a hot mild
detergent or soap solution. Dry thoroughly. Do not use
abrasives.
Nickel Plated – Wash when cool with a hot mild detergent or
soap solution. Do not use abrasives.
Stainless Steel – Normal soil may be removed with a
detergent or soap solution applied with a cloth.