NuTone AD-500 Directives D'installation page 2

Masquer les pouces Voir aussi pour AD-500:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

100920 AD500 Install instruct
Contents
Introduction ..........................................2
Operation ..............................................2
Hardware Features ................................2
Software Highlights ..............................2
Remote Keypads....................................2
Feature Overview ..................................3
Database Overview ................................3
Component Location..............................4
Wiring Diagram......................................5
Important Mounting requirements ........6
Entry System Mounting ........................7
Entry System Mounting (Continued) ....8
Relay Output Wiring ..............................9
Power, Battery, & Ground Wiring ..........9
Telephone Wiring ................................11
Optional Radio Antenna ......................11
Optional Postal Lock............................12
Optional Remote Keypad ....................12
Programming with a Computer ..........13
Programming Over the Telephone ......14
Programming from the Local Keypad..14
Programming Reference......................15
Factory Settings ..................................15
Introduction
The Model AD-500 Telephone Entry & Access Control System
is designed for use as a primary access control device for gated
communities, parking garages, office buildings, apartment, dormitories,
hotels/motels, commercial buildings and recreational facilities with up to
250 residents or users.
Housed in a locked, rugged stainless steel faced enclosure, the AD-500
features a side-lit 12-key telephone style keypad with bright, easy-to-
read graphics, a backlit two-line directory display with programmable
welcome message, a built-in microphone, and speaker.
The two relay output channels can be programmed to control electric
door strikes, magnetic locks, door & gate operators, or barrier gates.
The system utilizes hands-free, full duplex telephone communications
between visitors and residents for granting access.
The system can be programmed locally using the keypad, remotely with
a touch tone telephone, or remotely using a computer equipped with a
modem and a web browser.
Before starting the installation, read and understand these instructions.
Become familiar with the illustrations and wiring diagrams. They will be a
guide to installing the system in an efficient and professional manner.
Operation
In a typical installation, the unit's memory would be programmed with
each resident's name and directory code number. Arriving visitors would
use the keypad on AD-500 to view the directory names and directory
number for the desired resident. Upon entering the directory number,
the AD-500 will automatically dial the resident's telephone number and
establish two-way voice communication between the visitor and the
resident. The resident will then have the option to grant or deny access to
the visitor by pressing a digit on their telephone.
In addition to the telephone entry, the AD-500 can grant access using
entry codes (up to 500 entry codes) at the local keypad. Interior and
exterior remote keypads are available.
2
1/14/06
10:38 AM
Page 2
Programming Notes ............................15
Setting Up Multiple Units ....................16
Changing the Master Password ..........16
Resident Data Programming................17
Entry Code Programming ....................18
Wireless Transmitter Programming ....19
System Options ..................................20
System Options (Continued)................21
System Options (Continued)................22
System Options (Continued)................23
System Utilities....................................24
System Adjustments............................25
System Diagnostics ............................25
AD-500 Operation ................................26
Specifications ......................................27
Dimension Drawing ............................27
Troubleshooting ..................................27
NuTone Limited Warranty ....................28
FCC Notice ..........................................28
Hardware Features
 TWO FORM "C" (N.O. & N.C) RELAYS
Each relay has 3-amp @ 30-volt rating
 REQUEST-TO-EXIT INPUTS
Activates the access device for exiting using a hardwired switch
 POSTAL SWITCH OPTION
Cabinet supports mounting a standard U.S.P.S, postal switch for mail carrier access
 SENSING INPUT
For sensing door position to control door-ajar and alarm features, or for access inhibit timer
 BUILT-IN ANNUNCIATOR
Programmable for beeps during output activations and chirps during keystrokes
 BUILT-IN MODEM
No add-on modem required for telephone communications with system
 MULTIPLE UNIT SUPPORT
Up to seven AD-500 units can be connected on the same telephone line
Software Highlights
 LOCALLY PROGRAMMABLE
All programming can be performed from the local keypad
 REMOTE TELEPHONE PROGRAMMING
All programming can be performed with a TouchTone
 REMOTE COMPUTER PROGRAMMING
No dedicated programmer required, web-style programming with a computer and a modem
 500 ENTRY CODES
Up to 500 entry codes can be used for gaining access
 2-6 DIGIT ENTRY CODE LENGTH
Entry code lengths can be customized for small or large installations
 250 RESIDENT DIRECTORY CAPACITY
Up to 250 residents can have directory numbers for telephone entry
 2-4 DIGIT DIRECTORY NUMBER LENGTH
Directory Numbers lengths can be customized for small or large installations
TM
telephone over the phone line

Publicité

Table des Matières
loading

Table des Matières