Canadian Spa North American 60Hz Mode D'emploi page 11

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

ELECTRICAL REQUIREMENTS FOR SWIM SPA
Your swim spa runs on 220V 60Hz. There are two configurations you
can run your swim spa on.
The minimum supply current is 60 Amps, in this configuration the
heater will disengage if all 4 pumps are turned on.
The second option is to have the heater on even when the spa is
running at full speed; in very cold climates this may be desirable
especially if using the spa outdoors in winter continually. In this
configuration a 60 Amp supply is required.
The size of the wire required will be determined by the distance to
the supply and the shielding method; your electrician will be able to
advise you of the required wiring for your specific situation.
Access
The swim spa will arrive assembled as a single unit on a pallet. It
will weigh approximately 2000-2500lb (depending on the model)
and cannot be disassembled. For this reason you will need to have a
crane or other mechanical method of unloading the spa and getting it
to your chosen site.
EL2000 Circuit Board (St Lawrence 13' and 16' Swim Spa)
H1
S
Installation: Electrical requirements
J8
H2
E
Owners Manual
We recommend you book a contract lift where the lifting company
will assess the situation and method of the lift and carry insurance in
case of accidental damage to the spa or the property. The spa
warranty does not cover damage from installation. It is the
responsibility of the customer or his agents be it crane company or
lift operator to assess the lift and control all aspects of moving the
spa. Canadian Spa Company will not take responsibility for any part
of moving the spa, and cannot advise on the methods used to move
the spa.
Base
The base for your swim spa must be a flat level surface that contacts
the entire base of the spa. We recommend 6 inches (15 cm) of
re-enforced concrete but any flat level base that is stable and will not
shift or settle will suffice. If sinking your spa into the ground you need
to provide adequate drainage for water so that the hole the spa sits in
cannot flood as this will damage the electronics and electrical
components. Also at least 3ft (1 metre) of access to the entire front of
the spa filters is required for component access. You are responsible
for providing adequate access in order to repair the spa in case of
fault.
SA
SB
J91
Expander Board - 55026: for pump 3 & 4 (split plug)
10
CIRCUIT BOARD CODES:
E = 1 x Earth Screw
S = 7 x Standard Screws
H1 = Heater Connection '1'
H2 = Heater Connection '2'
SA = Sensor Port 'A'
SB = Sensor Port 'B'
T-Pad 1/2/3 = Topside Ports 1, 2 & 3
(Molex Connector)
JUMPER:
J8 = Jumper on 1 pin when using
1.5kW Heater. Jumper on 2 pin when
using 5.5kW Heater
J91 = Jumper on 1 pin enables Real
Time Clock function (ML900), Jumper
on 2 pin disables RTC function

Publicité

Table des Matières
loading

Table des Matières