Function Switch Introduction - Cotek SP Serie Manuel D'utilisation

Masquer les pouces Voir aussi pour SP Serie:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

EN
LED status
Orange
Orange Fast
Blink
Orange Slow
Blink

3-1-3. Function Switch Introduction

3-1-3-1. Function Switch Definition
Dip Switch
S1
S2
S3
S4
3-1-3-2. Output voltage selection (S1&S2)
Output voltage
100V/200V
110V/220V
115V/230V
120V/240V
22
Status
Device startup
process abnormal
Under Temperature
Protection
(Heat sink temp.
under -20℃)
Over Temperature
Protection
(Heat sink temp.
over 80℃)
Table 17. Inverter LED Status Indicator
Table 18. Function Switch Definition
S1
OFF
ON
OFF
ON
Table 19. Function Switch definition: output voltage selection
Note! 100V series can be selected between
100/110/115/120VAC, and 200V series can be selected
between 200/220/230/240VAC.
Recovery point
> 0℃
< 60℃
(heat sink temperature)
Figure 10. DIP switch ON/OFF position
Function
Voltage select
Voltage select
Frequency Select
Power saving ON/OFF
S2
OFF
OFF
ON
ON