Gas Piping: Gas piping shall be of such size and so installed as to provide a supply of gas sufficient to
Regulator information: ¾" NPT (National Pipe Thread) inlet and outlet; factory adjusted for four (4")
inch Water Column (WC) Natural Gas standard and may be converted by qualified personnel to be
used for Propane at ten (10") Water Column pressure.
Prior to connecting the regulator, check the incoming line pressure. The regulator can only withstand a
maximum pressure of ½ PSI (14" WC). If the line pressure is beyond this limit, a step down regulator
before the regulator provided will be required. The arrow forged into the bottom of the regulator body
shows gas flow direction, and should point downstream to the appliance.
CAUTION: Any loose dirt or metal particles, which are allowed to enter the gas lines on this appliance,
will damage the valve and affect its operation. When installing this appliance, all pipe and fittings must
be free from any internal contaminates. It is recommended that a "drip leg" be installed in-line before
the regulator. See diagram above.
Manual Shut Off Valve: A manual shut off valve should be installed upstream from the manifold,
within four (4) feet, (1.2M) of the appliance and in a position where it can be reached in the event of an
emergency.
Checking For Gas Leaks: Using a gas leak detector or a soapy water solution is recommended for
locating gas leaks. Matches, candle flame, or other sources of ignition shall not be used for this
purpose. Check entire piping system for leaks.
DO NOT use an open flame to check for leaks. Check all gas piping for leaks with a soap and water
Range Owner's Manual Rev 20180822
meet the full gas input of the appliance. If the
appliance is to be connected to existing piping, it
should be checked to determine if it has adequate
capacity. Joint compound (pipe dope) should be used
sparingly and only on the male threads of the pipe
joints. Such compounds must be resistant to the
action of Liquefied Propane (LP) gases.
 
WARNING
solution before operating the unit.
7
For Warranty Service Call 866-909-2855