Unit Door; Ventilation Of The Kitchen Unit - Atag KD80122AFN Instructions De Montage

Congélateurs et réfrigérateurs, intégrables, porte fixe
Masquer les pouces Voir aussi pour KD80122AFN:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Unit door

u Align the kitchen unit using a spirit level and marking square
and if necessary compensate with shims.
u Ensure that the floor and walls of the unit are at right angles
to one another.
6 Unit door
One door is required for the kitchen unit.
-
-
The door must be minimum 16 mm and maximum 19 mm
thick.
-
There must be a gap of minimum 3 mm width between the
door and the unit door located above it (if one exists).
The width of the unit door depends on the style of the
-
kitchen and the gap size between the door panels of the
cabinet. Generally, there should remain a vertical gap of
3 mm between the unit doors.
-
If other cabinets are present, the top edge of the unit door
should be on a level with the doors of the adjoining units.
-
The unit door must be planar and mounted stress-free.
NOTICE
Risk of damage from over-heavy unit door!
If the unit door is too heavy, damage to the hinges and resulting
impairment of function cannot be excluded.
u Before mounting the unit door, make sure that the door does
not exceed the approved unit door weight.
Appliance model
KD80102ADN
KD80122AFN
KD80140ADN, KD80140AFN,
KD80140BFN, KD80140CDN
KD80178AFN, KD80178CDN
14
Maximum cabinet
door weight (kg)
13
19
21
26

7 Ventilation of the kitchen unit

-
There must be an effective ventilation shaft of at least
200 cm
per appliance at the air inlet
2
Fig. 3 (B) vent.
The principle applies that the larger the ventilation shaft, the
-
more energy-saving the operation of the appliance.
-
The depth of the ventilation shaft at the back of the cabinet
must be min. 40 mm.
-
The upper ventilation shaft can either be positioned directly
above the appliance with an optional ventilation grille
Fig. 4 (C) , close to the ceiling above the unit Fig. 4 (D) or as
an air outlet opening in a false ceiling
* Depending on model and options
Fig. 3
Fig. 3 (A) and outlet
Fig. 4
Fig. 4 (E) .