Installation Guide
Installer system test
How to Use the Installer System Test
The Installer Test is part of the Installer Setup Menu.
1. Enter the Installer System Test by entering
Installer Setup.
2. The test appears at the end of the Installer
Setup Numbers.
3. See above for available Installer System
Tests.

Error codes

027
Faulty thermostat (must be replaced)
035
Duplicate thermostat zone detected
036
Duplicate UV timer
037
Duplicate filter timer
038
Duplicate humidifier pad timer
039
Duplicate indoor humidity sensor
040
Compressor should be running but it is not
050
Duplicate outdoor temperature sensor
052
Faulty post-coil air discharge sensor

Accessories

Please contact your distributor to order replacement parts.
Outdoor temperature sensor ............................Part number C7089U1006
Remote indoor temperature sensor .................Part number C7189U1005
Discharge air temp. sensor ..............................Part number C7835A1009
Energy recovery ventilator ................................Part number ER200B2006
Heat recovery ventilator ...................................Part number HR200B1005
Fresh air damper ...............................................Part number EARD6
2-Channel Telephone access module .............Part number W8735D1009
4-Channel Telephone access module .............Part number W8735D1017
Bypass flow-through or steam humidifier .......Part number HE265A1007
UV air purifier .....................................................Part number UV100E1043
Cover plate ........................................................Part number 32003796-001
(Use to cover marks left by old thermostats.)
*Contact your dealer or Honeywell rep for a complete list of compatible products.
For assistance with this product please visit
or call Honeywell Customer Care toll-free at
69-1816EFS—07
4. If installed with a Discharge Air
Temperature Sensor (ISU365=1), press
MORE to view the discharge temperature,
and press CANCEL to return to the Installer
test screen.
053
Faulty outdoor temperature sensor
054
Faulty indoor humidity sensor
089
Heating/cooling equipment is missing
090
Data interface is continuously busy
091
Thermostat is not receiving data from other
equipment
118
Faulty discharge air temperature sensor
119
Faulty temperature sensor
121
Duplicate post-coil air discharge sensor