Endress+Hauser Easytemp TMR31 Instructions D'opération page 35

Masquer les pouces Voir aussi pour Easytemp TMR31:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

TMR31, TMR35
Electromagnetic compatibility (EMC)
EMC meets all relevant requirements listed under IEC/EN 61326 Series and NAMUR NE21. Details as per declaration of
conformity.
ESD (Electrostatic
discharge)
Electromagnetic fields
Burst (fast transient)
Surge
Conducted RF
All EMC measurements were performed with a turn down (TD) = 2:1. Maximum fluctuations during EMC- tests: < 1 %
of measuring span.
Interference immunity to IEC/EN 61326 - series, requirements for industrial areas
Interference emission to IEC/EN 61326 - series, electrical equipment Class B.
Condensation
Permitted
Electrical safety
• Protection class III
• Overvoltage category II
• Pollution degree 2 III
Endress+Hauser
IEC/EN 61000-4-2
IEC/EN 61000-4-3
IEC/EN 61000-4-4
IEC/EN 61000-4-5
IEC/EN 61000-4-6
6 kV cont., 8 kV air
0.08 to 2 GHz
2 kV
0.5 kV sym.
0.01 to 80 MHz
Technical data
10 V/m
10 V
35

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Easytemp tmr35

Table des Matières