► Remove the container from the bottom sec­
tion of the CT-VA module.
► Fit the new container onto the bottom sec­
tion of the CT-VA module.
The system is ready to use.
7.4
Volumetric flow monitoring (only dust
class M)
For safety reasons, an acoustic warning signal
sounds if the air speed in the extraction hose
falls below 20 m/s.
The table on the pre-separator ex­
plains the connection between the de­
vice and the minimum required ex­
traction volume of the respective hose
diameter. If the extraction volume
falls below the required value, the
mobile dust extractor emits a warning
signal.*
We recommend that you adjust the hose to
work with Festool mobile dust extractors as fol­
lows:
L
27 mm
3,5 m
41 m³/h
32 mm
3,5 m
58 m³/h
36 mm
3,5 m
73 m³/h
* only with EU versions of CT AC
8

Transportation

The system [8] allows for dust-free transport:
► Disconnect the mobile dust extractor from
the connecting hose [8-1].
► Insert the free end into the free extraction
opening [8-2] on the CT-VA module.
► Connect both ends of the extraction
hose [8-3] to each other.
► Wind up the extraction hose.
► If necessary, use the plug [8-4] to seal the
mobile dust extractor.
Do not stack more than three full
containers on top of each other.
Observe all national regulations for load­
ing safety.
M
32
36
42
9

Maintenance and cleaning

WARNING
Hazardous dust
Damage to the respiratory passage
► Before removing the mobile dust extractor
from the contaminated area, clean it and
all accessories by thoroughly vacuuming
and washing them down (interior and exte­
rior).
► Parts that cannot be thoroughly cleaned
must be sealed in an airtight plastic bag
during transportation.
► Wear a dust mask.
Customer service and repairs
must only be carried out by the
manufacturer or service work­
shops. Find the nearest address
at: www.festool.com/service
Always use original Festool
EKAT
4
spare parts. Order no. at:
www.festool.com/service
5
3
2
1
Cleaning the pre-separator [9]
► Open the top section of the CT-VA module
using the T-Loc.
► Remove the electrical outlet module [10-3]
before cleaning.
► Remove cyclone parts from the top section
of the CT-VA module.
► Clean parts using light alkaline solutions at
up to 70 °C and leave to dry.
► Insert the bottom section of the cyclone
[9-3] horizontally.
► Insert the top section of the cyclone [9-2]
while ensuring that the catch is on the
right-hand side. Position the catch correct­
ly.
► Insert the extraction elbow [9-1] horizontal­
ly.
► Insert the electrical outlet module [10-3].
► Close the top section of the CT-VA module.
► Close the T-Loc.
► Insert the connecting hose and connect it to
the mobile dust extractor.
The system is ready to use.