Setup And Installation

3.
Setup And Installation

AC Power

Net-X™ has an internal auto-ranging power supply that works with an input voltage range of
100–240 VAC, 50/60 Hz. To determine the power requirements for the Net-X™ refer to the
label affixed to the product or Technical Specifications.
The listed rating indicates the maximum current draw during normal operation. For more
information,
www.chauvetprofessional.com.
·
Always connect this product to a properly grounded and protected
circuit.
·
Never connect this product to a rheostat (variable resistor) or dimmer
circuit, even if the rheostat or dimmer channel serves only as a 0 to
100% switch.
·
To eliminate unnecessary wear and improve its lifespan, during periods
of non-use completely disconnect the product from power via breaker or
by unplugging it.

Fuse Replacement

The Net-X uses a T 250 mA, 250 V fuse accessible from the back of the product. To change
the fuse, do the following:
1. Disconnect the product from power.
2. With a flat-head screwdriver, unscrew the fuse holder cap from the
housing.
3. Remove the blown fuse.
4. Replace with a fuse of the same type and rating.
5. Screw the fuse holder cap back in place and reconnect power.
·
Disconnect the product from power before replacing the fuse.
·
Always replace a blown fuse with another of the same type and rating.