Wiring Diagram; Terminal Block - CDVI CZ3000 Mode D'emploi

Masquer les pouces Voir aussi pour CZ3000:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

C - Surface mount (Optional: KCZ3000 kit)
1
(x8)
Measure and mark the center lines to
determining the magnet position on the
jamb and the armature plate on the door
leaf frame. Then drill the fixing screw
holes to fasten the screws easily.
Important: The surface housing can be
mounted in horizontal or in vertical in the
secure side.

5] WIRING DIAGRAM

Terminal block

+
Input voltage 12 V or 24 VDC*
-
Input voltage 12 V or 24VDC*
NC
Normally closed contact
C
Common
NO
Normally open contact
4
CZ3000
Self-aligning Magnetic Shearlock
2
1
2
Mount the brackets of the housing on
the jamb and on the door leaf. Insert
the cable and fasten temporarily the
magnet and the armature plate to
the bracket of the housing. Unfasten
the screws on the side of the arma-
ture plate (1) with the Allen key.
Then adjust the gap between the
magnet and the armature plate by
adjusting the top screws on the arma-
ture, allow 2mm distance maximum.
Tighten the 2 screws on the side of the
armature plate (2) once the test on
magnet has been successfull.
1
1
2
* Input voltage: 12 VDC or 24 VDC
3
2
Fasten definitively the magnet on the door
and place the housings.
24VDC
12VDC
The magnet can be powered in 12 VDC
or in 24 VDC according to the jumper
settings.
EN
(x2)

Publicité

Table des Matières
loading