1

Safety Instructions

The unit may only be connected to a protection low-voltage system
with safe electrical separation. The unit may only be opened and
repaired by the supplier. Never touch any electronic components of
the sensor.
2
Description of the Sensor
Merkur 2 ES.SM detects the direction in compliance with standards. The sensor
is also self-monitoring and type tested according to DIN 18650.
Article
Merkur 2 ES.SM.R.C
Merkur 2 ES.SM.F.C
Merkur 2 ES.SM.F
Merkur 2 ES.SM.V.C
Merkur 2 ES.SM.V
1
2
3
9
Cover
1
Plug-in screw terminal
2
RJ12 PCB socket
3
Grid for swivelling
4
the microwave module
Grid for tilting
5
the microwave module
Microwave double field module
6
Green LED
7
2 ES.SM
Signal output
Connection
Relay
RJ connector
Frequency
RJ connector
Frequency
Plug-in screw terminal
Voltage
RJ connector
Voltage
Plug-in screw terminal
1
1
8
7
6
5
4
14
12
13
11
10
Red LED
8
Recess for fastening
9
the sensor
Floor plate
10
Cable feed-through
11
DIP switch (addressing)
12
Key [<]
13
Key [>]
14
opening sensor for automatic doors in
3
Installation
3.1

Installation instructions

- The sensor must be mounted on a flat surface
(avoid vibrations)
- The sensor must be protected from rain and snow
- Objects (e.g. plants, flags, fans etc.) must not extend into the
detection area
- The sensor must not be obscured by covers/signs
- Fluorescent tubes should not be placed in the immediate vicinity of the
detection area
3.2

Opening the housing

BEFORE installation
2
9
3.3
Mounting
3
3
4
4
Affix drilling jig to wall/ceiling and drill holes according to instructions
1
Route cable through the appropriate opening in the floor plate –
2
make sure length is sufficient for wiring
Fasten sensor
3
Connect cable (according to type plate or chap. 3.4)
4
Click cover onto floor plate
5
Microwave motion detector as an
escape and emergency routes
AFTER installation
2
5
1
5
5
3
4
2

Publicité