Electrical Connections; Adjustable Parameters; Sensor Configuration - Bircher Reglomat Merkur2 ES.SM.R.C Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

3.4

Electrical connections

Model
Connection type
RJ12
Plug-in screw terminal
Merkur 2 ES.SM.R.C
* Both relay contacts are electrically isolated. Connecting the two contacts in series or in parallel is not permitted for safety reasons. Each contact must be evaluated
separately by the door controller. The initial state is only correct if the state of both relay contacts is the same. The door controller has to periodically verify this relay
output function according to the relevant standards requirements.
Combination of several Merkur 2 ES.SM for escape and rescue routes
According to AutSchR, signal sensors must fully release the escape route
without an explicit request, i.e. at any point across the full width of the door up
to at least 1.50 m before the door panels. This requires two sensors depending
on the door size. The following combination of two Merkur 2 ES.SM.R outputs is
the only approved option:
Control unit with two
Merkur 2 ES.SM.R.C
inputs for the
relay signal
Important:
All other combinations are not permitted! A separate input must be available for
each Merkur 2 ES.SM.F / Merkur 2 ES.SM.V if the door controller has a frequen-
cy or voltage input.
4
Displays on the Sensor
Red LED = function indication
→ object is detected
lights up
→ no object is detected
dark
→ safety opening
flashes
(self-monitoring of the system)
Green LED = status indication
→ SMD active
lights up
→ SMD not active
dark
5

Sensor Configuration

The sensor can be configured in two ways:
→ With keys on the sensor (basic settings), chap. 5.1
→ With the remote control (complete setting options), chap. 5.2
Merkur 2 ES.SM.R.C *
white
+
12–36 V DC
black
12–28 V AC
blue
yellow
green
red
Not available
Merkur 2 ES.SM.R.C
Merkur 2 ES.SM.F.C
white
+
12–36 V DC
˜
black
12–28 V AC
blue
U in –
yellow
F out
green
U in +
12–36 V DC
red
n ot connected
Merkur 2 ES.SM.F
white
1
+
12–36 V DC
˜
black
2
brown
U in –
3
F out
blue
4
U in +
12–36 V DC
5
Connect PIN 1 and 5 using a wire bridge
5.1
Configuration with keys
General procedure
1)
Keep [<] and [>] pressed for a corresponding length of time; every 2 s the
green LED will flash once
2)
Frequency of the flashing green LED (1-9 times) indicates current parameter
level
3)
The parameter level can be decreased or increased with [<] and [>]
respectively
4)
Press [<] and [>] briefly to exit the programming mode (settings are saved)
5.1.1

Adjustable parameters

Field size: Press [<] and [>] for 2 s
1, 2, 3
small
4, 5, 6* medium
7, 8, 9
large
Functionality: Press [<] and [>] for 4 s
1*
forwards, mounting height standard
2
forwards, mounting height high
3
backwards, mounting height standard
4
backwards, mounting height high
5
direction recognition OFF, mounting height standard
6
direction recognition OFF, mounting height high
Field geometry: Press [<] and [>] for 6 s
1
narrow field
2*
wide field
Restore factory settings: Press [<] and [>] for 8 s
Merkur 2 ES.SM.V.C
white
+
12–36 V DC
black
12–28 V AC
blue
U out –
yellow
U out +
green
not connected
red
n ot connected
Merkur 2 ES.SM.V
white
+
12–36 V DC
1
black
12–28 V AC
2
brown
U out –
3
blue
4
U out +
5
not connected
[>]
[<]
* Factory setting

Publicité

Table des Matières
loading

Produits Connexes pour Bircher Reglomat Merkur2 ES.SM.R.C

Table des Matières