Napoleon PVA40 Instructions D'installation page 3

Terminaison mécanique
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

VENT LENGTHS
It is recommended that the gas power vent be used with a gas appliance
that is equipped with Electronic Ignition. When installing the venting, these
parameters supersede the Vent Installation Section in the appliance's
Installation and Operating Instructions, as well as the following guidelines:
Maximum horizontal vent run with no rise is 70 feet total.
H = HORIZONTAL RUN
MAX H+V
70 FEET
MULTI ELBOW
Multi-elbow installations are possible up to a maximum of six 90°.
MAX
V1+V2+V3+
H1+H2+H3
70 FEET
DOWNWARD VERTICAL VENTING
Downward venting installations are only allowed when the
appliances is set to Intermittent Pilot Ignition (I.P.I.) Electronic
Ignition (E.I.). If an anti-condensation switch (standing
pilot) is being used, downward vertical venting is not
allowed.
MAX
MIN
H1+H2+V
H1+H2+V
70 FEET
10 FEET
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada • (705)721-1212 • fax (705)722-6031 •
V = VERTICAL RUN
MIN H+V
MAX ELBOWS
10 FEET
MIN
MAX
ELBOWS
V1+V2+V3+
H1+H2+H3
10 FEET
SIX 90°
MAX D
ELBOWS
8 FEET
SIX 90°
SIX 90°
MAX
www.napoleonfireplaces.com
3

Publicité

Table des Matières
loading

Table des Matières