ALGEMENE INFORMATIE
Algemeen
Dit is de montage-instructie voor de op de voorzijde aangegeven Novy-afzuigkap. De gebruiksaanwijzing is een apart
boekje dat ook bij deze afzuigkap is meegeleverd. Lees deze instructies goed door voor de installatie en ingebruikname
van de vlakschermkap. Het is aan te bevelen om de installatie uitsluitend te laten uitvoeren door één of meerdere bevoegde
personen.
Neem de afzuigkap zorgvuldig uit de verpakking. Controleer aan de hand van de tekeningen op pagina 2 of alle
montagematerialen meegeleverd zijn.
The hood is to be used above a cooking plate and/or domino and it is intended for household use only. The built-in unit
is to be placed in a self-constructed recessed housing.
The recommended minimum overall height is: 60 cm over an electrical/ceramic cooking plate, 65 cm over a gas or an
induction cooking plate. The recessed housing must at least fully bridge the cooking plate. The built-in unit is preferably
mounted centralised over the cooking zones.
Important before mounting
Page 2 of these mounting instructions show the mounting drawings. Observe the following mounting tips before starting
the mounting activities:
• For easier mounting of the telescopic hood it is recommended to do this with at least 2 persons.
• Check if all mounting materials have been supplied using the drawings on page 2.
• Position the wall socket such that it is near the telescopic hood.
Exhaust or recirculation
Before starting any mounting activities, you must have made the choice if you are going to make an exhaust duct to the
outside or if you are going to use the hood as a recirculation hood. In case of an exhaust duct to the outside, carefully
read the section in these mounting instructions for installing the exhaust duct. For recirculation, please separately order
the recirculation kit.
INSTALLATION
Proceed following the mounting drawings on page 2.
Make a cut-away:
1
Type 828:
525 mm x 275 mm
Type 829:
825 mm x 275 mm
• The built-in unit is to be mounted into a robust mounting plate (with minimum thickness of 18 mm and a maximum
thickness of 35 mm).
• It is recommended to finish the cut-away in a watertight way.
• It is advised to mount the mounting plate which the built-in unit is to be placed into recessed by about 10 cm. This
increases the catching capacity.
• A wall socket must be near the built-in unit. The built-in unit has a cable with earthed plug and must be connected
to an earthed wall socket. The amperage and the consumption have been indicated on the specification label at-
tached to the inside of the built-in unit.
There are 2 installation methods:
• Installation method 1: Standard installation using clamping springs
• Installation method 2: Alternative installation that only applies when the recessed housing has a partition at a
height of 280 mm
Installation method 1:
Position the built-in unit in the cut-away of the recessed housing and push it upwards. The clamps on the sides of
2
the built-in unit are resting on the sides of the recessed housing.
If necessary (when there is a partition at a height of 280 mm), loosen the 4 indicated screws and remove them from
3
the hood. Attention! A cut-away is to be made in the partition for the exhaust duct.
Take the aluminium fat filter from the built-in unit.
4
By tightening the clamping screws both on the left and on the right side the built-in unit is firmly mounted in the
5
housing.
After this place the fat filter back into the hood again.