5.4
INSTALLATION OF NON-COMBUSTIBLE BOARD
WARNING: Non-combustible facing material must not project more than 4" (102mm) from the face of the
door (all three sides). If greater projections are desired, increase the clearance to the sides and top by 2"
(51mm) for every additional 1" (25mm) of projection. If using an optional surround, the same rule applies,
starting from the top of the surround. Ensure clearances are maintained for surround removal, as it must lift
off the appliance for maintenance.
3"(76.2mm)
2" (50.8mm)
0" (0mm)
DOOR WITH
SAFETY
BARRIER
6" (152.4mm)
5" (127mm)
4" (101.6mm)
TOP OF
APPLIANCE
3"
[76mm]
31 1/2"
[80cm]
N O N
- C O M
27"
[94cm]
C O M
B U S
N O N
- C O M
C O M
B U S
B U S
T I B L
E
[144mm]
T I B L
E
B U S
T I B L
E
T I B L
E
4 1/2"
W415-1442 / D / 12.01.16
33
EN