MINIMUM ENCLOSURE CLEARANCES

TOP VENT
EN
53"
[134.6cm]
CEILING
(MIN.)
31 1/2"
[80cm]
TOP EXIT ENCLOSURE
The appliance requires a minimum enclosure height of 53" (134.6cm). For temperature requirements, the
enclosure space around and above the appliance must be left unobstructed.
NOTE: The vent shield is telescopic and must be adjusted to shield the full depth of the combustible
wall penetration.
* See "MINIMUM FRAMING DIMENSION" section for details on reducing vent pipe top clearances.
These parameters also apply to the illustrations found in the "MINIMUM ENCLOSURE CLEARANCES" section.
W415-1442 / D / 12.01.16
5" [127mm]
STEEL HEADER
TOP OF
4 1/2"
APPLIANCE
[114mm]
OPENING
NON-COMBUSTIBLE
MATERIAL
COMBUSTIBLE
MATERIAL
NON-COMBUSTIBLE
COMBUSTIBLE
7" [178mm]
MIN.
1" [25mm]
3" [76mm]
0" (0mm) IF
NON-COMBUSTIBLE
FINISHING IS USED
SUCH AS BRICK
AND STONE.
1" [25mm]
41 1/8"
[104.5cm]
MIN. PLUS
*
RISE