Technical data
Inside measurement range
Precision (typical)*
Laser class
Laser wavelength
Power supply
Dimensions
Weight (incl. batteries)
Auto switch-off
Operating temperature
Storage temperature
Article number
* measuring distance up to 10 m with strongly reflective target surface
and at room temperature. The measurement deviation may increase by
± 0.2 mm/m for greater distances and under unfavourable measuring
conditions such as strong sunlight or weakly reflective target surfaces.

Error codes:

Err101:
Replace the battery
Err104:
Calculation error
Err152:
Temperature is too high: > 40°C
Err153:
Temperature is too low: < 0°C
Err154:
Outside the measuring range
Err155:
Received signal too weak
Err156:
Received signal too strong
Err157:
Incorrect measurement or background is too bright
Err160:
The device is moving too much to measure.
EU directives and disposal
This device complies with all necessary standards
for the free movement of goods within the EU.
This product is an electric device and must be
collected separately for disposal according to
the European Directive on waste electrical and
electronic equipment.
Further safety and supplementary notices at:
www.laserliner.com/info
DistanceMaster 100
(Subject to technical change without notice 11.15)
0.05 m - 100 m
± 1.5 mm
2 < 1mW
635 nm
2 x AAA 1.5 Volt batteries
124 x 51 x 27 mm
217 g
28 s for laser / 2.45 min for device
-10°C – 40°C
-20°C – 70°C
080.946A