Control and indicator elements

9.1

Toggle switch

Position 'T'
Postion 'T' activates the calibration process.
The LED 'AlarmT' respectively 'AlarmR' light up
simultaneously for the duration of the calibration.
During this time, the protected area must be clear.
If defect or covered elements are detected, the
number of elements is shown by either the AlarmR
LED flashing for receiver elements or the AlarmT
LED flashing for emitter elements.
For example: If the LED AlarmT flashes three times
after calibration, three of the emitter elements are
either covered or defective.
9.2

LED - Indicators

Power
Internal 5 V ok
SigOut
Relay on (short flash = self test ok)
SigIn
Input status of SigIn (on = HIGH)
On = HIGH (must be "HIGH" during operation)
AlarmR
Diagnostic LED receiver edge
AlarmT
Diagnostic LED emitter edge
    
    
LED description
LED off
LED on
LED not relevant (on / off)
LED flashes
8
T 0
Description
The light curtain carries out a calibration cycle. It controls the intensity of the emitter in a
way that the receiver has a defined signal. The length of calibration is between 1 and 5 s
Alternating flashing of LED's AlarmR and AlarmT indicate a self test at power up (approx.
10 s)
Pos '0'
Normal operation.
Buzzer off.
Receiver
Pos
Buzzer activated, as soon as
light curtain is interrupted.
Transmitter
© CEDES | V 2.7