Pro Series VS FloPro™ Series Variable-Speed Pump
®
FILTER
HEATER
CHECK VALVE
(Check Valve recommended
for systems installed with Erosion Feeders
or Aquapure
®
salt chlorination systems)
SPA RETURN
Figure 2.
Typical Piping Installation
NOTE
When the pool equipment is located below the
pool surface a leak can result in large scale water
loss or flooding. Zodiac Pool Systems, Inc., cannot be
responsible for such water loss or flooding or damage
caused by either occurrence.
3.
Install the pump such that any disconnecting means
and/or junction boxes for power connection are
within sight of the pump and at least fi ve (5) feet
horizontally from the edge of the pool and/or spa.
Choose a location that will minimize turns in the
piping.
NOTE
In Canada, the minimum distance maintained from
the edge of the pool and/or spa as noted above must be
3 meters (10 feet), as required by the Canadian Electrical
Code (CEC, CSA C22.1).
4.
The pump must be placed on a solid foundation that
will not vibrate. To further reduce the possibility of
vibration noise, bolt the pump to the foundation, or
place it on a rubber mat.
NOTE
Zodiac Pool Systems, Inc. recommends bolting the
pump directly to the foundation.
5.
The pump foundation must have adequate drainage
to prevent the motor from getting wet. Protect the
pump from the rain and sun.
6.
Proper ventilation is required for the pump to
operate normally. All motors generate heat that
must be removed by providing proper ventilation.
|
Installation & Operation Manual
PUMP
a.
POOL
RETURN
POOL/SPA
3 WAY VALVE
SKIMMER
a.
MANUAL BY-PASS DETAIL:
USE WHEN FILTRATION RATE
EXCEEDS 125 GPM FOR ZODIAC
HEATERS. REFER TO THE MANUFAC-
TURER'S RECOMMENDATIONS IF
USING A DIFFERENT BRAND HEATER.
7.
Provide access for future services by leaving a clear
area around the pump. Allow plenty of space above
the pump to remove the lid and basket for cleaning.
8.
If the equipment is in a potentially dark area,
provide adequate lighting.

Pipe Sizing

For assistance with suction and discharge pipe sizing,
please see Table 1.

Installation Recommendations

1.
To help prevent diffi culty in priming, install the
suction pipe without high points (above inlet
of pump - inverted "U"s, commonly referred to
in plumbing as an airlock) that can trap air. For
installations of equipment up to 100 feet (30 m)
from the water, refer to Table 1, the pipe sizing
chart. For installations of equipment more than 100
feet (30 m) from the water, the recommended pipe
size must be increased to the next size.