Jandy Pro Series VS FloPro Série Manuel De Fonctionnement Et D'installation page 11

Pompe à vitesse variable
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Jandy
Pro Series VS FloPro™ Series Variable-Speed Pump
®
AquaLink
RS RS-485 Connectors
®
S1
S2
5-Position
DIP Switch
200 ft (61 m)
max install distance
for communication
4-Position
DIP Switch
Figure 7.
Wiring AquaLink RS Controller or
AquaLink PDA
3.
Slide dip switches 1 and 2 down to the OFF
position. If applicable to your pump model slide
dip switch 5 up to the ON position. See Figure 7.
4.
Select the desired address(es) for the pump by
setting dip switches 3 and/or 4, as shown in Section
3.3, VS FloPro Pump Dip Switch Settings.
5.
If short RS485 cable or JEP-R controller is pre
installed:
a. Disconnect the RS485 cable from the 4-pin
header on the pump drive.
Note: Do not cut the cable, or you will lose the ability to return
to the default factory configuration.
b. Connect the new RS-485 cable from the
AquaLink through the available compression
fitting and route the 4-conductor cable through
the motor drive threaded port closest to the
connector. Figure 7.
|
4 3 2 1
4 3 2 1
6 5 4 3 2 1
10 9 8 7 6 5 4 3 2 1
RS6 & RS8 ONLY
RS8 ONLY
POOL MODE
RESET
AUTO
SPA MODE
SPA DRAIN
SERVICE
HEATER
SOLAR
TIME OUT
SPA FILL
Connect to
AquaLink RS
4 3 2 1
RS-485 Connector
(or Multiplexer
Interface Board)
Variable-Speed
Pump
Power Wiring
Port
Product may differ from images shown
Installation & Operation Manual
6.
Connect the RS-485 connector on the
AquaLink
matching wire colors with connector positions as
follows: 1-red, 2-black, 3-yellow, and 4-green. See
Figure 7.
7.
Restore power to the pump and verify the operation
of the controller.
.
Refer to the appropriate manual for set up and
operation of the pump: AquaLink RS Owner's
Manual, 6593, AquaLink PDA Owner's Manual,
H0572300, or AquaLink Z4™ Owner's Manual,
H0386600.
JEP-R Remote Mounting
The variable-speed controller may be remote mounted
onto a vertical surface that is protected from the
elements.
Follow the directions carefully to maintain the ability
to reinstall the variable-speed controller onto the Pump.
Reverse these instructions to complete the reinstallation.
See Figure 8.
ELECTRICAL SHOCK HAZARD
Turn off all switches and the main breaker in the variable-
speed pump electrical circuit before starting the procedure.
Failure to comply may cause a shock hazard resulting in
severe personal injury or death.
Controller Rear
Loosen
to remove
(x4)
Controller
Base
Access Cover
Figure 8.
Disconnect Variable-Speed Controller
from Pump
ENGLISH
RS (or multiplexer interface board),
®
WARNING
Pump
Motor
Cover
Power Wiring Port
Page 11
RS-485 Cable
DO NOT CUT

Publicité

Table des Matières
loading

Table des Matières