Jandy Pro Series VS FloPro Série Manuel De Fonctionnement Et D'installation page 10

Pompe à vitesse variable
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Page 10
ENGLISH
Table 3.
Recommended Wire Sizes for VS FloPro Pumps
RECOMMENDED MINIMUM WIRE SIZE FOR VS FLOPRO PUMPS*
Distance from Sub-panel
Model
VS-FHP1.0, VSFHP165AUT, VSFHP165JEP
VS-FHP2.0, VSFHP270AUT, VSFHP270JEP
*Assumes three (3) copper conductors in a buried conduit and 3% maximum voltage loss in branch circuit. All National Electrical Code
®
(NEC
) or the Canadian Electrical Code (CSA) and local codes must be followed. Table shows minimum wire size and branch fuse
recommendations for typical installation.
WARNING
Make sure that the control switch, time clock, or
control system is installed in an accessible location,
so that in the event of an equipment failure or a loose
plumbing fitting, the equipment can be turned off. This
location must not be in the same area as the pool
pump, filter, and other equipment.
The pump must be permanently connected to a
dedicated electrical circuit. No other equipment,
lights, appliances, or outlets may be connected to the
pump circuit, with the exception of devices that may
be required to operate simultaneously with the pump,
such as a chlorinating device or heater.
Breaker Panel
GROUND
GFCI
Figure 6.
Bonding the Motor
Electrical Wiring
1.
The pump motor must be securely and adequately
grounded using the green screw provided. Ground
before attempting to connect to an electrical power
supply. Do not ground to a gas supply line.
2.
Wire size must be adequate to minimize voltage
drop during the start-up and operation of the pump.
See Table 3 for suggested wire sizes.
Jandy
Pro Series VS FloPro™ Series Variable-Speed Pump
®
Class: CC, G, H, J, K, RK, or T
CAUTION
Bonding Lug
Terminal Block
Variable-Speed
Pump (230 VAC)
Branch Fuse AMPS
230 VAC
15A
20A
3.
Insulate all connections carefully to prevent
grounding or short-circuits. Sharp edges on
terminals require extra protection. For safety, and to
prevent entry of contaminants, reinstall all conduit
and terminal box covers. Do not force connections
into the conduit box.
NOTE
When power alone is supplied to this pump, it will not
operate. It requires a digital command sent to it by either
a variable speed controller (JEP-R), an AquaLink
controller, an AquaLink Pool Digital Assistant (PDA), or
an AquaLink Z4™, to operate at a chosen speed.
VS FloPro Controller Options
The VS FloPro pump can be operated by one (1)
of four (4) controllers: the JEP-R variable-speed
controller, the AquaLink RS controller (Rev O or later),
the AquaLink PDA (Rev 4.0 or later), or the AquaLink
Z4. The VS FloPro variable-speed pump communicates
with the controllers via a four-wire RS-485 interface.
Controller Installation Options
The VS-FHP1.0, VSFHP165JEP, VS-FHP2.0, &
VSFHP270JEP pumps come pre-configured for the
JEP-R variable-speed controller with DIP switch
settings pre-configured to work with this controller. The
VSFHP165AUT and VSFHP270AUT Pumps come
pre-configured for installation with the AquaLink RS,
AquaLink PDA, or AquaLink Z4.
To install with an AquaLink RS controller (Rev O
or later), an AquaLink PDA (Rev 4.0 or later), or an
AquaLink Z4:
1.
Remove power from the VS FloPro pump by
disconnecting the high voltage lines or by turning
off any breaker to which the VS FloPro pump
power is connected.
Turn off all switches and the main breaker in the variable-
speed pump electrical circuit before starting the procedure.
Failure to comply may cause a shock hazard resulting in
severe personal injury or death.
2.
Remove the access cover to complete electrical
connections to the motor.
|
Installation & Operation Manual
0-150 Feet
(0-45 metres)
Gauge of Wire
Voltage
230 VAC
12
10
WARNING
ELECTRICAL SHOCK HAZARD
®
RS
®

Publicité

Table des Matières
loading

Table des Matières