Page 8
ENGLISH
No Base Required
Hayward
Option
Pentair
1
Sta-Rite
Small Base
Option
Hayward Super II™
Jandy PlusHP by Zodiac
2
Jandy Max HP by Zodiac
Small Base with Spacers
Option
Pentair WhisperFlo
3
Sta-Rite Dyna-Glas™
Small Base + Large Base
Sta-Rite Max-E-Pro
Option
Sta-Rite Dura-Glas
4*
Sta-Rite Dura-Glas II
Sta-Rite Max-E-Glas
Figure 3.
VS FloPro Pump and Base Options
Table 1.
Pipe Sizing Chart for Schedule 40 PVC
Pipe Size
Maximum Flow
Suction
(6 feet per second)
1½"
37 GPM (140 LPM)
(38 mm)
2"
62 GPM (235 LPM)
(51 mm)
2½"
88 GPM (333 LPM)
(64 mm)
3"
136 GPM (515
(76 mm)
LPM)
4"
234 GPM (886
(102 mm)
LPM)
2.
VS FloPro Pumps come equipped with unions on
both the suction and discharge ports. This feature
simplifies installation and service and eliminates
the possibility of leaks at threaded adapters.
3.
The VS FloPro Pump must be connected to at least
two (2) hydraulically-balanced main drains for each
pool pump suction line. Each drain (suction outlet)
assembly must be provided with covers and must be
listed or certified to the latest published edition of
ANSI
/ASME
A112.19.8, or its successor standard,
®
®
Jandy
Pro Series VS FloPro™ Series Variable-Speed Pump
®
VS FloPro with Small Base
®
Super Pump
®
Pump
®
SuperFlo
®
Height
Suction
®
SuperMax
®
Side
Height
®
®
®
®
* Optional
®
(Order R0546400)
Maximum Flow
Discharge
(8 feet per second)
50 GPM (189 LPM)
85 GPM (322 LPM)
120 GPM (454
LPM)
184 GPM (697
LPM)
313 GPM (1185
LPM)
ANSI/APSP-16. The suction fittings of the main
drains must be at least three (3) feet (1 m) apart or at
different planes. The suction fittings can be a drain
and skimmer, two (2) drains, two (2) skimmers, or a
skimmer with an equalizer line installed. Check the
local codes for proper installation.
NOTE
To prevent entrapment, the system must be built so
it cannot operate with the pump drawing water from only
one (1) main drain. At least two (2) main drains must be
connected to the pump when it is in operation. However, if
two (2) main drains run into a single suction line, the single
suction line may be equipped with a valve that will shut off
both main drains from the pump.
4.
The piping must be well supported and not forced
together where it will experience constant stress.
5.
Always use properly sized valves. Jandy Pro Series
Diverter Valves and Ball Valves typically have the
best flow capabilities.
6.
Use the fewest possible fittings especially 90 degree
elbows. Each additional fitting or length of pipe
increases resistance to flow which makes the pump
work harder.
NOTE
If more than ten (10) suction fittings are needed, the
pipe size must be increased.
|
Installation & Operation Manual