AEG HC652600EB Notice D'utilisation page 34

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

34 www.aeg.com
• Seal the gap between the worktop
and glass ceramic with silicone.
• Put some soapy water on the silicone.
8.5 The installation of more than one appliance
Added parts:connection bar(s), heat re-
sistant silicon, rubber shape, sealing
strap.
580 mm
min.
38 mm
min.
2 mm
+
-
=
360 mm
20 mm
920 mm
• Pull off the excess silicone with the
scraper.
Only use special a heat - resistant
silicon.
The worktop cut out
Distance from the wall : minimum 50 mm
Depth : 490 mm
Width : sum widths of all the appliances
to be built-in and subtract 20 mm (see
also "Overview of all appliance widths" )
min.
12 mm
min.
2 mm

Publicité

Table des Matières
loading

Table des Matières