Technical Specifications

Model
120S
240S
240D
Setpoint range
- F mode: 5 °C to 40 °C (40 °F to 104 °F)
- A/AF mode: 5 °C to 30 °C (40 °F to 86 °F)
Floor limit range - AF mode: 5 °C to 40 °C (40 °F - 104 °F)
Display range
- F mode: 0 °C to 60 °C (32 °F to 140 °F)
- AF mode: 0 °C to 50 °C (32 °F to 122 °F)
Resolution: 0.5 °C (1 °F)
Heating cycle length: 15 minutes
Data protection: All settings are saved during a power failure.
Supply
Maximum current
120 VAC, 50/60Hz
240 VAC, 50/60Hz
208 VAC, 50/60Hz
240 VAC, 50/60Hz
208 VAC, 50/60Hz
Maximum wattage
16.7 A
2000 W
4000 W
16.7 A
3470 W
3600 W
15 A
3120 W
13
TH114-A/AF-120S/240S/240D
Wiring
4 wires / single pole
4 wires / single pole
4 wires / double pole